Management of Aortic Valve Dysfunction After Transapical Approach Using the Technique “Valve After Valve”

We report a case of a 77-year-old patient with severe aortic stenosis who underwent transapical aortic valve implantation with a 23-mm Edwards Sapien valve (Edwards Lifesciences Inc, Irvine CA). This procedure was complicated with the occurrence of an acute regurgitation due to entrapment of one of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2011-09, Vol.92 (3), p.1102-1104
Hauptverfasser: Miranda-Balbuena, Nuria, MD, Araji, Omar A., MD, PhD, Gutierrez-Martín, Maria Ángeles, MD, Rodriguez-Caulo, Emiliano A., MD, Barquero, Jose Miguel, MD, Fernandez, Antonio, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We report a case of a 77-year-old patient with severe aortic stenosis who underwent transapical aortic valve implantation with a 23-mm Edwards Sapien valve (Edwards Lifesciences Inc, Irvine CA). This procedure was complicated with the occurrence of an acute regurgitation due to entrapment of one of the leaflets that was successfully managed by valve after valve technique.