Large foreign body reaction to tension-free vaginal tape masquerading as inguinal hernia
We report a case of a 73-year-old woman who presented to general surgery with a tender lump in the groin 5 years after insertion of a tension-free vaginal tape. The lesion was thought to be an incarcerated inguinal hernia. Emergency surgical exploration revealed a 7 × 5 × 4 cm soft tissue mass which...
Gespeichert in:
Veröffentlicht in: | International Urogynecology Journal 2011-09, Vol.22 (9), p.1193-1195 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report a case of a 73-year-old woman who presented to general surgery with a tender lump in the groin 5 years after insertion of a tension-free vaginal tape. The lesion was thought to be an incarcerated inguinal hernia. Emergency surgical exploration revealed a 7 × 5 × 4 cm soft tissue mass which was adherent to the external inguinal ring, emanating from the end of the tension-free vaginal tape at the level of the symphysis pubis. Resection and histological examination revealed a central track of granulation tissue with a surrounding foreign body inflammatory response. The surgery was complicated by an infected seroma requiring surgical drainage and antibiotic therapy, following which the patient made a full recovery. Large foreign body reaction is a rare but an important complication of tension-free vaginal tapes and may be mistaken for a groin hernia or lymphadenopathy. |
---|---|
ISSN: | 0937-3462 1433-3023 |
DOI: | 10.1007/s00192-011-1412-5 |