Fetal MRI clues to diagnose cloacal malformations

Background Prenatal US detection of cloacal malformations is challenging and rarely confirms this diagnosis. Objective To define the prenatal MRI findings in cloacal malformations. Materials and methods We performed a retrospective study of patients with cloacal malformations who had pre- and post-n...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pediatric radiology 2011-09, Vol.41 (9), p.1117-1128
Hauptverfasser: Calvo-Garcia, Maria A., Kline-Fath, Beth M., Levitt, Marc A., Lim, Foong-Yen, Linam, Leann E., Patel, Manish N., Kraus, Steven, Crombleholme, Timothy M., Peña, Alberto
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Prenatal US detection of cloacal malformations is challenging and rarely confirms this diagnosis. Objective To define the prenatal MRI findings in cloacal malformations. Materials and methods We performed a retrospective study of patients with cloacal malformations who had pre- and post-natal assessment at our institution. Fetal MRI was obtained in six singleton pregnancies between 26 and 32 weeks of gestation. Imaging analysis was focused on the distal bowel, the urinary system and the genital tract and compared with postnatal clinical, radiological and surgical diagnoses. Results The distal bowel was dilated and did not extend below the bladder in five fetuses. They had a long common cloacal channel (3.5–6 cm) and a rectum located over the bladder base. Only one fetus with a posterior cloacal variant had a normal rectum. Three fetuses had increased T2 signal in the bowel and two increased T1/decreased T2 signal bladder content. All had renal anomalies, four had abnormal bladders and two had hydrocolpos. Conclusion Assessment of the anorectal signal and pelvic anatomy during the third trimester helps to detect cloacal malformations in the fetus. The specificity for this diagnosis was highly increased when bowel fluid or bladder meconium content was identified.
ISSN:0301-0449
1432-1998
DOI:10.1007/s00247-011-2020-8