Calibration of a wide angle stereoscopic system
Inaccuracies in the calibration of a stereoscopic system appear with errors in point correspondences between both images and inexact points localization in each image. Errors increase if the stereoscopic system is composed of wide angle lens cameras. We propose a technique where detected points in b...
Gespeichert in:
Veröffentlicht in: | Optics letters 2011-08, Vol.36 (16), p.3064-3066 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Inaccuracies in the calibration of a stereoscopic system appear with errors in point correspondences between both images and inexact points localization in each image. Errors increase if the stereoscopic system is composed of wide angle lens cameras. We propose a technique where detected points in both images are corrected before estimating the fundamental matrix and the lens distortion models. Since points are corrected first, errors in point correspondences and point localization are avoided. To correct point location in both images, geometrical and epipolar constraints are imposed in a nonlinear minimization problem. Geometrical constraints define the point localization in relation to its neighbors in the same image, and eipolar constraints represent the location of one point referred to its corresponding point in the other image. |
---|---|
ISSN: | 0146-9592 1539-4794 |
DOI: | 10.1364/OL.36.003064 |