Arterial line in prehospital emergency settings – A feasibility study in four physician-staffed emergency medical systems

Abstract Background and aim of the study Arterial lines are widely used in operating rooms, critical care and emergency departments. Although invasive arterial blood pressure monitoring and arterial blood gas analysis are prehospitally available, the use of arterial lines in the field remains an exc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Resuscitation 2011-09, Vol.82 (9), p.1198-1201
Hauptverfasser: Wildner, Gernot, Pauker, Nina, Archan, Sylvia, Gemes, Geza, Rigaud, Marcel, Pocivalnik, Mirjam, Prause, Gerhard
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background and aim of the study Arterial lines are widely used in operating rooms, critical care and emergency departments. Although invasive arterial blood pressure monitoring and arterial blood gas analysis are prehospitally available, the use of arterial lines in the field remains an exception. This study evaluates the feasibility, indications and therapeutic consequences of prehospital arterial line insertion. Methods Prospective observational study in four physician-staffed emergency medical systems (EMS), documenting patient status, indications, location of puncture, number of tries and time for puncture and therapeutic consequences. Results During the one-year observation period, arterial line placement succeeded in 115 (83.9%) of 137 patients. The median time for successful arterial cannulation was 2 min (IQR 1, 3 min; range: 30–600 s), for preparing the invasive blood pressure monitoring 3 min (IQR 2, 4 min, range: 30–600 s). Main indications were cardiopulmonary resuscitation (36.5%), post-resuscitation care (16.8%), respiratory insufficiency (24.1%) and unconsciousness (22.6%). Therapeutic consequences depended on whether the EMS was equipped with a blood gas analyzer or not and were, overall, reported in 51.3% of patients: fluids, vasoactive or antihypertensive therapy, correction of ventilation or acidosis. No complications occurred during the prehospital phase. Conclusion The insertion of arterial lines is feasible under prehospital conditions, without delaying or complicating patient care. Indications originating from intrahospital use are also valid in the field. In particular when combined with arterial blood gas measurement, the use of arterial lines often leads to important therapeutic consequences.
ISSN:0300-9572
1873-1570
DOI:10.1016/j.resuscitation.2011.05.002