Comparison between laser speckle contrast imaging and laser Doppler imaging to assess skin blood flow in humans

We tested the linearity between skin blood flux recorded with laser speckle contrast imaging (LSCI) and laser Doppler imaging (LDI), comparing different ways of expressing data. A secondary objective was to test within-subject variability of baseline flux with the two techniques. We performed local...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Microvascular research 2011-09, Vol.82 (2), p.147-151
Hauptverfasser: Millet, C., Roustit, M., Blaise, S., Cracowski, J.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We tested the linearity between skin blood flux recorded with laser speckle contrast imaging (LSCI) and laser Doppler imaging (LDI), comparing different ways of expressing data. A secondary objective was to test within-subject variability of baseline flux with the two techniques. We performed local heating at 36, 39, 42, and 44 °C on the forearm of healthy volunteers, and measured cutaneous blood flux with LDI and LSCI. Biological zero (BZ) was obtained by occluding the brachial artery. We expressed data as raw arbitrary perfusion units (APUs) and as a percentage increase from baseline (%BL), with and without subtracting BZ. Inter-site variability was expressed as a within subject coefficient of variation (CV). Twelve participants were enrolled. Inter-site variability at baseline was lower with LSCI (CV = 9.2%) than with LDI (CV = 20.7%). We observed an excellent correlation between both techniques when data were expressed as raw APUs or APU − BZ (R = 0.90; p < 0.001). The correlation remained correct for %BL ( R = 0.77, p < 0.001), but decreased for %BL − BZ ( R = 0.44, p = 0.003). Bland–Altman plots revealed a major proportional bias between the two techniques. This study suggests that skin blood flux measured with LSCI is linearly related to the LDI signal over a wide range of perfusion. Subtracting BZ does not affect this linearity but introduces variability in baseline flux, thus decreasing the correlation when data are expressed as a function of baseline. Finally, systematic bias makes it impossible to assimilate arbitrary perfusion units provided by the two systems. [Display omitted] ► There is an excellent correlation between LSCI and LDI over a wide range of perfusion. ► Biological zero should not be subtracted when expressing data as a function of baseline. ► There is a systematic bias making comparison between the two techniques impossible.
ISSN:0026-2862
1095-9319
DOI:10.1016/j.mvr.2011.06.006