Development of a fully automated toxicological LC-MSn screening system in urine using online extraction with turbulent flow chromatography

In clinical toxicology, fast and specific methods are necessary for the screening of different classes of drugs. Therefore, an online extraction high-performance liquid chromatography coupled to mass spectrometry (LC-MSn) screening method using a MS² and MS³ spectral library for the identification o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical and bioanalytical chemistry 2011-04, Vol.400 (1), p.89-100
Hauptverfasser: Mueller, Daniel M, Duretz, Bénédicte, Espourteille, Francois A, Rentsch, Katharina M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In clinical toxicology, fast and specific methods are necessary for the screening of different classes of drugs. Therefore, an online extraction high-performance liquid chromatography coupled to mass spectrometry (LC-MSn) screening method using a MS² and MS³ spectral library for the identification of xenobiotic substances has been developed and validated. Samples were run twice, once native and once after enzymatic hydrolysis. Internal standards and buffer were added to the urine samples. Following centrifugation, the supernatant was injected into the system. Extraction was performed by online turbulent flow chromatography. The chromatographic separation was achieved using a Phenyl/Hexyl column. For detection, a linear ion trap, equipped with an APCI interface, was used and the different compounds were identified using a MS² and MS³ spectral library containing 356 compounds. The turnaround time to report the results of the screening including hydrolysis was approximately 2 h. About 92% of the 356 substances could be identified with a limit of identification below 100 ng/ml. The recovery and matrix effect experiments showed suitable results, and in six drug-free urine samples of healthy volunteers analyzed for selectivity, no substances have been identified. Carryover could be well controlled, and the method had a good reproducibility. The comparison of the results of 103 real patient urine samples showed a good agreement between the existing GC-MS and LC-MS methods with offline extraction and the new online extraction LC-MSn screening method. The presented method allows a fast and sensitive analysis of a broad range of compounds.
ISSN:1618-2642
1618-2650
DOI:10.1007/s00216-010-4560-4