Material model of lung parenchyma based on living precision-cut lung slice testing
We describe a novel constitutive model of lung parenchyma, which can be used for continuum mechanics based predictive simulations. To develop this model, we experimentally determined the nonlinear material behavior of rat lung parenchyma. This was achieved via uni-axial tension tests on living preci...
Gespeichert in:
Veröffentlicht in: | Journal of the mechanical behavior of biomedical materials 2011-05, Vol.4 (4), p.583-592 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We describe a novel constitutive model of lung parenchyma, which can be used for continuum mechanics based predictive simulations. To develop this model, we experimentally determined the nonlinear material behavior of rat lung parenchyma. This was achieved via uni-axial tension tests on living precision-cut rat lung slices. The resulting force–displacement curves were then used as inputs for an inverse analysis. The Levenberg–Marquardt algorithm was utilized to optimize the material parameters of combinations and recombinations of established strain–energy density functions (SEFs). Comparing the best-fits of the tested SEFs we found
W
p
a
r
=
4.1
kPa
(
I
¯
1
−
3
)
2
+
20.7
kPa
(
I
¯
1
−
3
)
3
+
4.1
kPa
(
−
2
ln
J
+
J
2
−
1
)
to be the optimal constitutive model. This SEF consists of three summands: the first can be interpreted as the contribution of the elastin fibers and the ground substance, the second as the contribution of the collagen fibers while the third controls the volumetric change. The presented approach will help to model the behavior of the pulmonary parenchyma and to quantify the strains and stresses during ventilation.
[Display omitted]
► A novel hyperelastic material model for viable lung tissue is presented. ► Continuum based simulations are a promising new approach to understand lung mechanics. ► Realistic material models for lung parenchyma are essential but not yet available. ► A protocol for uni-axial tension tests on living precision-cut rat lung slices was developed. ► Experiments have been combined with inverse analysis and a material tool box. |
---|---|
ISSN: | 1751-6161 1878-0180 |
DOI: | 10.1016/j.jmbbm.2011.01.006 |