Effect of decontaminating solutions on titanium surface: an in vitro study of human epithelial cell culture
The effects of three different decontaminating solutions in clinical use for peri-implantitis therapy on the chemical structure and surface roughness of commercially pure (CP) Ti were investigated. A further aim was to survey the response of the biological environment to these changes, by examining...
Gespeichert in:
Veröffentlicht in: | Fogorvosi szemle 2011-03, Vol.104 (1), p.9-18 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | hun |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The effects of three different decontaminating solutions in clinical use for peri-implantitis therapy on the chemical structure and surface roughness of commercially pure (CP) Ti were investigated. A further aim was to survey the response of the biological environment to these changes, by examining the attachment and proliferation of human epithelial cells after treatment of the Ti surfaces with these solutions.
CP (grade 4) machined titanium discs (CAMLOG Biotechnologies AG, Switzerland) were treated with 3% H2O2 (5 min), saturated citric acid (pH = 1; 1 min) or chlorhexidine gel (CHX, 5 min). The surface properties were followed through the use of X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The epithelial cell attachment and proliferation was examined by means of 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and bicinchoninic acid (BCA) protein-content assays.
XPS showed an intact TiO2 layer on each sample and CHX was adsorbed by the surface, as C-O and/or C=O bond formation was revealed. AFM results gave no significant changes in the roughness after treating the surfaces with the cleaning solutions. While MTT and BCA assays did not show significant differences in epithelial cell attachments, the cell proliferation was significantly increased after H2O2 treatment as compared to CHX (not shown by BCA assays).
The applied decontaminating agents do not damage the Ti surface. H2O2 can be used effectively in decontaminating the implants affected by peri-implantitis, as the human epithelial cell growth was improved, in contrast with CHX. |
---|---|