SEM Evaluation of the Root Canal Walls after Treatment with Tetraclean
Purpose In this ex vivo study, the surface cleanliness of root canal walls after shaping with Ni-Ti instruments and irrigating with different endodontic solutions was evaluated by SEM. Methods 50 single-rooted teeth were divided into 5 groups. All root canals were shaped with Revo-S™ (MICRO-MEGA®, B...
Gespeichert in:
Veröffentlicht in: | International journal of artificial organs 2010-09, Vol.33 (9), p.660-666 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
In this ex vivo study, the surface cleanliness of root canal walls after shaping with Ni-Ti instruments and irrigating with different endodontic solutions was evaluated by SEM.
Methods
50 single-rooted teeth were divided into 5 groups. All root canals were shaped with Revo-S™ (MICRO-MEGA®, Besancon, France) rotary Ni-Ti instruments and irrigated with NaOCl, varying the final rinse: NaOCl, Tetraclean, 17% EDTA, Cloreximid, Tetraclean liquid not mixed with powder. Specimens were fractured longitudinally and prepared for SEM analysis in order to evaluate the presence/absence of smear layer and the presence/absence of open tubules at the coronal, middle, and apical third of each canal, using a 3-step scale for scores. Numeric data were analyzed using Kruskall-Wallis test and Mann-Whitney U test and significance was predetermined at p |
---|---|