Analysis and Performance of Axial Flux Permanent-Magnet Machine With Air-Cored Nonoverlapping Concentrated Stator Windings
In this paper, the performance of air-cored (ironless) stator axial flux permanent magnet machines with different types of concentrated-coil nonoverlapping windings is evaluated. The evaluation is based on theoretical analysis and is confirmed by finite-element analysis and measurements. It is shown...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on industry applications 2008-09, Vol.44 (5), p.1495-1504 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper, the performance of air-cored (ironless) stator axial flux permanent magnet machines with different types of concentrated-coil nonoverlapping windings is evaluated. The evaluation is based on theoretical analysis and is confirmed by finite-element analysis and measurements. It is shown that concentrated-coil winding machines can have a similar performance as that of normal overlapping winding machines using less copper. |
---|---|