Nanosilver-penetrated polyion graphene complex membrane for mediator-free amperometric immunoassay of alpha-fetoprotein using nanosilver-coated silica nanoparticles
► We fabricate a polyion graphene complex membrane-based immunosensing platform for sensitive electrochemical immunoassay of alpha-fetoprotein. ► Nanosilver-coated silica nanocomposites as bionanolabels. ► Graphene nanosheets, single-stranded DNA and silver nanoparticles as matrices. ► Direct electr...
Gespeichert in:
Veröffentlicht in: | Electrochimica acta 2011-04, Vol.56 (11), p.3773-3780 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ► We fabricate a polyion graphene complex membrane-based immunosensing platform for sensitive electrochemical immunoassay of alpha-fetoprotein. ► Nanosilver-coated silica nanocomposites as bionanolabels. ► Graphene nanosheets, single-stranded DNA and silver nanoparticles as matrices. ► Direct electron transfer without electron mediator. ► Analysis of real samples and method comparison.
A facile and sensitive mediator-free electrochemical immunosensor for detection of alpha-fetoprotein (AFP) was designed by using nanosilver-coated silica nanoparticles (Ag-SiO
2) as bionanolabels. To construct such an electrochemical immunosensor, silver ions/single-stranded DNA/graphene nanosheets were initially immobilized on a gold electrode in turn, then silver ions were in situ reduced to silver nanoparticles with the aid of NaBH
4, and anti-AFP antibodies conjugated to silver nanoparticles were used. In the presence of AFP analyte, the sandwiched immunocomplex was formed on the electrode surface by using horseradish peroxidase-anti-AFP conjugate-labeled Ag-SiO
2 (HRP-anti-AFP-Ag-SiO
2) as secondary antibodies. Compared with pure silver nanoparticles, Ag-SiO
2 nanocomposites could provide a large room for the immobilization of HRP-anti-AFP, and improve the electrochemical responses of the immunosensor. Meanwhile, the presence of highly conductive graphene nanosheets and silver nanoparticles provided a good pathway for electron transfer. Under optimal conditions, the immunosensor exhibited good electrochemical responses toward AFP ranging from 0.3 to 200
ng/mL with a detection limit (LOD) of 0.05
ng/mL (at 3
σ) in pH 6.0 PBS-H
2O
2 system. Intra- and inter-assay displayed good precisions with coefficient of variation below 9.5%. In addition, the method was evaluated with 23 clinical serum samples, receiving good correlation with results from commercially available electrochemiluminescent analyzer. |
---|---|
ISSN: | 0013-4686 1873-3859 |
DOI: | 10.1016/j.electacta.2011.02.059 |