Derivatization of SWCNTs with cobalt phthalocyanine residues and applications in screen printed electrodes for electrochemical detection of thiocholine

► We have performed covalent attachment of cobalt phthalocyanine (CoPh) to SWCNTs via stable sulfonamide bonds, and have applied them on screen printing graphite electrodes. ► We have proved that the binding of CoPh moieties to SWCNT improves the electrocatalytic effect towards thiocholine (TCh) oxi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrochimica acta 2011-04, Vol.56 (11), p.3988-3995
Hauptverfasser: Jubete, Elena, Żelechowska, Kamila, Loaiza, Oscar A., Lamas, Pedro J., Ochoteco, Estibalitz, Farmer, Kevin D., Roberts, Kenneth P., Biernat, Jan F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:► We have performed covalent attachment of cobalt phthalocyanine (CoPh) to SWCNTs via stable sulfonamide bonds, and have applied them on screen printing graphite electrodes. ► We have proved that the binding of CoPh moieties to SWCNT improves the electrocatalytic effect towards thiocholine (TCh) oxidation and permits the decrease in the oxidation overpotential of TCh. ► The derivatization of this type of nanotubes with CoPh and their easy and durable deposition on screen-printed devices open new possibilities for the construction of highly sensitive pesticide biosensors, which work at low potentials without the need of high mediator loadings. Single-walled carbon nanotubes (SWCNTs) derivatized with cobalt phthalocyanine (CoPh) were applied onto screen-printed graphite electrodes (SPEs) to be used for the low-potential electrochemical oxidation of thiocholine (TCh). Covalent attachment of CoPh to SWCNTs via stable sulfonamide bonds was confirmed by Raman/FT-IR spectroscopy and thermogravimetric analysis (TGA) coupled with FT-IR detection. The resulting modified SPE surfaces (CoPh-SWCNT-SPEs) were characterized by cyclic voltammetry and electrochemical impedance spectroscopy (EIS) with the redox probe [F 3(CN) 6] 3−/4−. Detection of TCh was accomplished using cyclic voltammetry and amperometry; a lower overpotential (100 mV vs. Ag/AgCl pseudoreference electrode) was obtained using CoPh-SWCNT-SPEs as compared to unmodified SPEs and SPEs modified with non-functionalized SWCNTs (SWCNT-SPEs). The linear range for TCh detection was 0.077–0.45 mM, with a sensitivity of 5.11 × 10 −1 μA mM −1 and a limit of detection of 0.038 mM according to the 3 s/m definition.
ISSN:0013-4686
1873-3859
DOI:10.1016/j.electacta.2011.01.123