Derivatization of SWCNTs with cobalt phthalocyanine residues and applications in screen printed electrodes for electrochemical detection of thiocholine
► We have performed covalent attachment of cobalt phthalocyanine (CoPh) to SWCNTs via stable sulfonamide bonds, and have applied them on screen printing graphite electrodes. ► We have proved that the binding of CoPh moieties to SWCNT improves the electrocatalytic effect towards thiocholine (TCh) oxi...
Gespeichert in:
Veröffentlicht in: | Electrochimica acta 2011-04, Vol.56 (11), p.3988-3995 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ► We have performed covalent attachment of cobalt phthalocyanine (CoPh) to SWCNTs
via stable sulfonamide bonds, and have applied them on screen printing graphite electrodes. ► We have proved that the binding of CoPh moieties to SWCNT improves the electrocatalytic effect towards thiocholine (TCh) oxidation and permits the decrease in the oxidation overpotential of TCh. ► The derivatization of this type of nanotubes with CoPh and their easy and durable deposition on screen-printed devices open new possibilities for the construction of highly sensitive pesticide biosensors, which work at low potentials without the need of high mediator loadings.
Single-walled carbon nanotubes (SWCNTs) derivatized with cobalt phthalocyanine (CoPh) were applied onto screen-printed graphite electrodes (SPEs) to be used for the low-potential electrochemical oxidation of thiocholine (TCh). Covalent attachment of CoPh to SWCNTs
via stable sulfonamide bonds was confirmed by Raman/FT-IR spectroscopy and thermogravimetric analysis (TGA) coupled with FT-IR detection. The resulting modified SPE surfaces (CoPh-SWCNT-SPEs) were characterized by cyclic voltammetry and electrochemical impedance spectroscopy (EIS) with the redox probe [F
3(CN)
6]
3−/4−. Detection of TCh was accomplished using cyclic voltammetry and amperometry; a lower overpotential (100
mV
vs. Ag/AgCl pseudoreference electrode) was obtained using CoPh-SWCNT-SPEs as compared to unmodified SPEs and SPEs modified with non-functionalized SWCNTs (SWCNT-SPEs). The linear range for TCh detection was 0.077–0.45
mM, with a sensitivity of 5.11
×
10
−1
μA
mM
−1 and a limit of detection of 0.038
mM according to the 3
s/m definition. |
---|---|
ISSN: | 0013-4686 1873-3859 |
DOI: | 10.1016/j.electacta.2011.01.123 |