Index Loss Effect in n-Value Measurements of Commercial Superconductors
n-value of the superconductor is key parameter in the persistent magnet design, affecting cost and performance. Analysis is presented that shows that a few mK overheat from the nonlinear index loss during standard Ic measurement of NbTi and Nb 3 Sn conductors in the helium bath can significantly aff...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2009-06, Vol.19 (3), p.2313-2316 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | n-value of the superconductor is key parameter in the persistent magnet design, affecting cost and performance. Analysis is presented that shows that a few mK overheat from the nonlinear index loss during standard Ic measurement of NbTi and Nb 3 Sn conductors in the helium bath can significantly affect the measurements and produce artificially high n-values. The error increases in conductors with higher n. Effect of low heat transfer, E ref criterion and index stability crisis are discussed. Analytical correlation is presented between the apparent and actual n-values. |
---|---|