Impact of a computer-generated alert system on the quality of tight glycemic control

Purpose To assess the impact of a computer-generated blood glucose (BG) alert, generated by a Patient Data Management System (PDMS) and superimposed on a paper-based guideline, on tight glycemic control (TGC) in the intensive care unit (ICU). Methods TGC in the Leuven University Hospitals is perform...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Intensive care medicine 2011-07, Vol.37 (7), p.1151-1157
Hauptverfasser: Meyfroidt, Geert, Wouters, Pieter, De Becker, Wilfried, Cottem, Dominiek, Van den Berghe, Greet
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose To assess the impact of a computer-generated blood glucose (BG) alert, generated by a Patient Data Management System (PDMS) and superimposed on a paper-based guideline, on tight glycemic control (TGC) in the intensive care unit (ICU). Methods TGC in the Leuven University Hospitals is performed by nurses using a paper-based guideline that allows anticipative, intuitive decision-making. An electronic alert was implemented on 1 August 2007 in which a pop-up appears in the PDMS at the following BG thresholds: >180, >110, 60–80, 40–60 and