An implantable wireless biosensor for the immediate detection of upper GI bleeding: a new fluorescein-based tool for diagnosis and surveillance (with video)

Background Early recurrent hemorrhage after endoscopic intervention for acute upper GI bleeding (UGIB) can approach 20% and leads to increased morbidity and mortality. Little has changed over the past several decades regarding immediate posthemorrhage surveillance, and there has likewise been no sig...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastrointestinal endoscopy 2011-07, Vol.74 (1), p.189-194.e1
Hauptverfasser: Ryou, Marvin, MD, Nemiroski, Alex, BS, Azagury, Dan, MD, Shaikh, Sohail N., MD, Ryan, Michele B., MS, Westervelt, Robert M., PhD, Thompson, Christopher C., MD, MSc, FACG, FASGE
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Early recurrent hemorrhage after endoscopic intervention for acute upper GI bleeding (UGIB) can approach 20% and leads to increased morbidity and mortality. Little has changed over the past several decades regarding immediate posthemorrhage surveillance, and there has likewise been no significant improvement in outcomes. Objective To develop and test an endoscopically implantable wireless biosensor for real-time detection of fluorescein-labeled blood in ex vivo and in vivo porcine models of UGIB. Setting Animal laboratory. Design Benchtop and acute animal studies. Subjects Five pigs. Interventions UGIB models were surgically created in living pigs. Biosensors were endoscopically deployed in the stomach using standard endoscopic clips. The ability to detect acute UGIB and estimated blood loss leading to biosensor activation were recorded. Feasibility of wireless data transmission out of the body to an external computer and cell phone was assessed. Main Outcome Measurements Technical feasibility and immediate complications. Results A porcine UGIB model was successfully created. Biosensors were able to detect all acute bleeding events and wirelessly transmit out of the body, and successfully sent an emergency text message to the intended cell phone in all cases. Average estimated blood loss leading to biosensor activation was 30 mL (10–75 mL). Limitations Animal study; small numbers. Conclusions An endoscopically implantable wireless biosensor successfully detected acute hemorrhage in a porcine UGIB model and sent an emergency cell-phone alert in real time.
ISSN:0016-5107
1097-6779
DOI:10.1016/j.gie.2011.03.1182