Stability of hematologic analytes in monkey, rabbit, rat, and mouse blood stored at 4°C in EDTA using the ADVIA 120 hematology analyzer
Background: The time from sampling to analysis can be delayed when blood samples are shipped to distant reference laboratories or when analysis cannot be readily performed. Objective: The objective of this study was to evaluate the stability of hematologic analytes in blood samples from monkeys, rab...
Gespeichert in:
Veröffentlicht in: | Veterinary clinical pathology 2011-06, Vol.40 (2), p.188-193 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background: The time from sampling to analysis can be delayed when blood samples are shipped to distant reference laboratories or when analysis cannot be readily performed.
Objective: The objective of this study was to evaluate the stability of hematologic analytes in blood samples from monkeys, rabbits, rats, and mice when samples were stored for up to 72 hours at 4°C.
Methods: Blood samples from 30 monkeys, 15 rabbits, 20 rats, and 30 mice were collected into EDTA‐containing tubes and were initially analyzed within 1 hour of collection using the ADVIA 120 analyzer. The samples were then stored at 4°C and reanalyzed at 24, 48, and 72 hours after collection.
Results: Significant (P |
---|---|
ISSN: | 0275-6382 1939-165X |
DOI: | 10.1111/j.1939-165X.2011.00304.x |