Balloon-Assisted Deployment Prevents Endograft Misalignment During Hybrid Aortic Arch Repair

Misaligned deployment refers to eccentric flaring of the bare stent portion of the endograft that causes proximal device retroflexion resulting in suboptimal graft placement. A 71-year-old woman with 6.8-cm distal aortic arch aneurysm underwent hybrid repair with combination of open aortic arch debr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2011-06, Vol.91 (6), p.1982-1984
Hauptverfasser: Jassar, Arminder Singh, MBBS, Golden, Michael A., MD, Augoustides, John G., MD, FASE, Vernick, William J., MD, Bavaria, Joseph E., MD, Szeto, Wilson Y., MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Misaligned deployment refers to eccentric flaring of the bare stent portion of the endograft that causes proximal device retroflexion resulting in suboptimal graft placement. A 71-year-old woman with 6.8-cm distal aortic arch aneurysm underwent hybrid repair with combination of open aortic arch debranching and subsequent thoracic endovascular aortic repair. During endograft deployment, misaligned opening occurred; this was corrected by using a balloon-assisted graft deployment. Follow up imaging continues to demonstrate complete aneurysm exclusion. Misaligned deployment is a clinical challenge; we hereby present a previously undescribed technique to accommodate this limitation of the current endograft technology.
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2010.11.022