Optimization of pressurized liquid extraction and purification conditions for gas chromatography–mass spectrometry determination of UV filters in sludge
This work presents an effective sample preparation method for the determination of eight UV filter compounds, belonging to different chemical classes, in freeze-dried sludge samples. Pressurized liquid extraction (PLE) and gas chromatography–mass spectrometry (GC–MS) were selected as extraction and...
Gespeichert in:
Veröffentlicht in: | Journal of Chromatography A 2011-01, Vol.1218 (2), p.211-217 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This work presents an effective sample preparation method for the determination of eight UV filter compounds, belonging to different chemical classes, in freeze-dried sludge samples. Pressurized liquid extraction (PLE) and gas chromatography–mass spectrometry (GC–MS) were selected as extraction and determination techniques, respectively. Normal-phase, reversed-phase and anionic exchange materials were tested as clean-up sorbents to reduce the complexity of raw PLE extracts. Under final working conditions, graphitized carbon (0.5
g) was used as in-cell purification sorbent for the retention of co-extracted pigments. Thereafter, a solid-phase extraction cartridge, containing 0.5
g of primary secondary amine (PSA) bonded silica, was employed for off-line removal of other interferences, mainly fatty acids, overlapping the chromatographic peaks of some UV filters. Extractions were performed with a n-hexane:dichloromethane (80:20, v:v) solution at 75
°C, using a single extraction cycle of 5
min at 1500
psi. Flush volume and purge time were set at 100% and 2
min, respectively. Considering 0.5
g of sample and 1
mL as the final volume of the purified extract, the developed method provided recoveries between 73% and 112%, with limits of quantification (LOQs) from 17 to 61
ng
g
−1 and a linear response range up to 10
μg
g
−1. Total solvent consumption remained around 30
mL per sample. The analysis of non-spiked samples confirmed the sorption of significant amounts of several UV filters in sludge with average concentrations above 0.6
μg
g
−1 for 3-(4-methylbenzylidene) camphor (4-MBC), 2-ethylhexyl-p-methoxycinnamate (EHMC) and octocrylene (OC). |
---|---|
ISSN: | 0021-9673 1873-3778 |
DOI: | 10.1016/j.chroma.2010.11.028 |