An analysis of the performance of an anaerobic dual anode-chambered microbial fuel cell
The performance of a dual anode-chambered microbial fuel cell (MFC) inoculated with Shewanella oneidesis MR-1 was evaluated. This reactor was constructed by incorporating two anode chambers flanking a shared air cathode chamber in an electrically parallel, geometrically stacked arrangement. The devi...
Gespeichert in:
Veröffentlicht in: | Journal of power sources 2011-02, Vol.196 (4), p.1909-1914 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The performance of a dual anode-chambered microbial fuel cell (MFC) inoculated with
Shewanella oneidesis MR-1 was evaluated. This reactor was constructed by incorporating two anode chambers flanking a shared air cathode chamber in an electrically parallel, geometrically stacked arrangement. The device was shown to have the same maximum power density (approximately 24
W
m
−3, normalized by the anode volume) as a single anode-, single cathode-chambered MFC. The dual anode-chambered unit generated a maximum current of 3.66
mA (at 50
Ω), twice the value of 1.69
mA (at 100
Ω) for the single anode-chambered device at approximately the same volumetric current density. Increasing the Pt-coated cathode surface area by 100% (12 to 24
cm
2) had no significant effect on the power generation of the dual anode-chambered MFC, indicating that the performance of the device was limited by the anode. The medium recirculation rate and substrate concentration in the anode were varied to determine their effect on the anode-limited power density. At the highest recirculation rate, 5
ml
min
−1, the power density was about 25% higher than at the lowest recirculation rate, 1
ml
min
−1. The dependence of the power density on the lactate concentration showed saturation kinetics with a half-saturation constant
K
s on the order of 4.4
mM. |
---|---|