International comparability in spectroscopic measurements of protein structure by circular dichroism: CCQM-P59

Circular dichroism is a spectroscopic technique that is widely used to obtain information about protein structure, and hence is an important tool with many applications, including the characterization of biopharmaceuticals. However, there is a lack of confidence in the technique, arising from an obs...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Metrologia 2010-01, Vol.47 (1A), p.08022-8022
Hauptverfasser: Ravi, Jascindra, Schiffmann, David, Tantra, Ratna, Cox, Simon, Eady, Jonathan, Jones, Christopher, Vrettos, John S, Affleck, Richard P, DeSa Lorenz, Julie, Shigeri, Yasushi, Linghui, Sheng, Jun, Liu, Willows, Robert, Charlet, Philippe, Dupont, Yves, Meuse, Curtis W, Bailey, Marc J A, Knight, Alex E
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Circular dichroism is a spectroscopic technique that is widely used to obtain information about protein structure, and hence is an important tool with many applications, including the characterization of biopharmaceuticals. However, there is a lack of confidence in the technique, arising from an observed lack of comparability in the data obtained by different laboratories, or even different operators. In this study, we set out to determine the extent of comparability in the technique, by comparing the results obtained from identical protein samples by a panel of worldwide laboratories. The laboratories chosen were either national measurement institutes (NMIs) or expert laboratories nominated by an NMI. We also aimed to identify the main factors contributing to any lack of measurement comparability. Data were analysed using PCA and SIMCA methods, and we show these statistical techniques are ideal for analysing large amounts of this type of spectroscopic data. We found a startling lack of comparability among laboratories, but we also found that most of the variability arose from relatively simple problems, which can be avoided by following simple guidelines. We believe that the lack of an absolute reference or measurement traceability in circular dichroism contributes to a lack of confidence in the technique. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM Working Group on Bioanalysis (BAWG).
ISSN:0026-1394
1681-7575
1681-7575
DOI:10.1088/0026-1394/47/1A/08022