Blood-viscosity and Vascular Flow Rate Blood-viscosity Measured in a Cone-plate Viscometer and the Flow Rate in an Isolated Vascular Bed

The whole-blood viscosity measured in a cone-plate viscometer and the flow ratio estimated in the vascular bed of an isolated rabbit ear have been compared for different blood samples. The reciprocal ratio between the flow rate of human blood and the flow rate of saline in the vascular bed was stati...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scandinavian journal of clinical and laboratory investigation 1968, Vol.21 (1), p.83-88
Hauptverfasser: Skovborg, F., Nielsen, Aa. V., Schlichtkrull, J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The whole-blood viscosity measured in a cone-plate viscometer and the flow ratio estimated in the vascular bed of an isolated rabbit ear have been compared for different blood samples. The reciprocal ratio between the flow rate of human blood and the flow rate of saline in the vascular bed was statistically significantly correlated to the haematocrit value. The estimated flow ratio in the vascular bed was approximately proportional to the viscosities measured in the cone-plate viscometer. The closest proportionality was found at shear rate 5.75 sec-1. The flow rate of blood relative to saline was at all shear rates found to be higher than expected from the measured viscosities. This indicates that the Fåhræus-Lindqvist effect is effective in the vascular bed.
ISSN:0036-5513
1502-7686
DOI:10.3109/00365516809076980