Arch replacement and downstream stent grafting in complex aortic dissection: first results of an international registry
Abstract Objectives: Arch replacement combined with antegrade stent grafting of the descending aorta represents a hybrid surgical approach for extensive thoracic aortic disease. This multicentre study evaluates the early results of this method in complex aortic dissection (AD). Methods: Retrospectiv...
Gespeichert in:
Veröffentlicht in: | European journal of cardio-thoracic surgery 2011-01, Vol.39 (1), p.87-94 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Objectives: Arch replacement combined with antegrade stent grafting of the descending aorta represents a hybrid surgical approach for extensive thoracic aortic disease. This multicentre study evaluates the early results of this method in complex aortic dissection (AD). Methods: Retrospective data acquisition was achieved by institution of an international registry. A hybrid stent graft with integrated vascular prosthesis for arch replacement (E-vita open®) was used. From January 2005 to March 2009, 106 patients (mean age 57; 77% male) with complex AD (55 acute, 51 chronic) were studied. Results: As many as 49/106 (46%) patients underwent emergency surgery. Stent-graft deployment and arch replacement (95 total, 11 subtotal) were performed under hypothermic circulatory arrest (HCA (8 ± 6 min) and selective antegrade cerebral perfusion (SACP) (74 ± 23 min). Stent-graft placement into the true lumen was successful in all but one case (99%). Ascending aortic replacement was performed in 91/106 (86%), aortic valve repair/replacement in 49/106 (46%), coronary artery bypass grafting (CABG) in 17/106 (16%) and mitral valve repair in 2/106 (2%). Cardiopulmonary bypass (CPB) and cardiac arrest times were 242 ± 64 and 144 ± 44 min, respectively. In-hospital mortality was 12% (13/106; six acute, seven chronic AD) and new strokes observed in 5/106 (5%). The false lumen (FL) was evaluated in 96/106 (91%) patients postoperatively. At first follow-up computed tomography (CT)-examination, thoracic FL thrombosis was 93% (76 complete, 13 partial) and 58% (31 complete, 25 partial) in the thoraco-abdominal aorta. Conclusions: By combining arch replacement with downstream stent grafting, one-stage repair of complex aortic dissection with almost unanimous thoracic FL thrombosis can be achieved at acceptable perioperative risk. |
---|---|
ISSN: | 1010-7940 1873-734X |
DOI: | 10.1016/j.ejcts.2010.03.070 |