Positive correlation of optical density at 650 nm. with lecithin/sphingomyelin ratios in amniotic fluid

In this study, we have attempted to correlate optical density measurements of amniotic fluids with L/S ratios. We may conclude, with over a 98 per cent accuracy, that fluids having optical density readings of 0.15 and above, at 650 nm. will have an L/S ratio over 2.0. Fluids having optical density r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of obstetrics and gynecology 1978-04, Vol.130 (7), p.788-790
Hauptverfasser: Sbarra, Anthony J., Selvaraj, Ratnam J., Cetrulo, Curtis L., Kennedy, Joseph L., Herschel, Marguerite J., Knuppel, Robert, Kappy, Kenneth, Mitchell, George W., Kelley, Edward C., Paul, Benoy B., Louis, Farid J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, we have attempted to correlate optical density measurements of amniotic fluids with L/S ratios. We may conclude, with over a 98 per cent accuracy, that fluids having optical density readings of 0.15 and above, at 650 nm. will have an L/S ratio over 2.0. Fluids having optical density readings up to 0.05 will have L/S ratios of about 1.3. Finally, amniotic fluids having optical densities >0.05 and