Intercomparison of Myocardial Imaging Agents: 201TI, 129Cs, 43K, and 81Rb
Thallium-201, 129Cs, 43K, and 81Rb were evaluated as "static" myocardial-imaging agents. Optimal settings of the scintillation camera were determined for each agent. Accumulation for good-quality images can be started as early as 5 min after the dose with 43K, 10 min with 201T1, and 30 min...
Gespeichert in:
Veröffentlicht in: | The Journal of nuclear medicine (1978) 1976-10, Vol.17 (10), p.880-889 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Thallium-201, 129Cs, 43K, and 81Rb were evaluated as "static" myocardial-imaging agents. Optimal settings of the scintillation camera were determined for each agent. Accumulation for good-quality images can be started as early as 5 min after the dose with 43K, 10 min with 201T1, and 30 min with 129Cs. Imaging times were comparable for 43K, 129Cs, and 201T1 (using the 80-keV x-rays). High-energy photons from the 81Rb preparation, largely from 82mRb contaminant, made it impossible to obtain an interpretable image without the addition of more shielding. Absorbed radiation dose from 81Rb is lower than that from 43K, 129Cs, and 201T1. The highest background activity was observed with 81Rb, followed by 43K, 129Cs, and 201T1 in that order. Overall, 201T1 was best suited for imaging acute myocardial infarction with currently available equipment, and 129Cs was next best. However, because of instrument setting and commercially obtained preparations, 81Rb could not be properly compared with the other radionuclides in our study. |
---|---|
ISSN: | 0161-5505 1535-5667 |