Infection of cardiac suture line after ventricular aneurysmectomy. Report of two cases

Two cases of sepsis following ventricular aneurysmectomy are presented. In both, the source of sepsis was an infected caridac suture line in which Teflon felt strips were used to reinforce the closure. One patient had a pseudoaneurysm and a chronic empyema of the left side of the chest, and the seco...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of thoracic and cardiovascular surgery 1976-08, Vol.72 (2), p.280-281
Hauptverfasser: Looser, KG, Allmendinger, PD, Takata, H, Ellison, LH, Low, HB
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Two cases of sepsis following ventricular aneurysmectomy are presented. In both, the source of sepsis was an infected caridac suture line in which Teflon felt strips were used to reinforce the closure. One patient had a pseudoaneurysm and a chronic empyema of the left side of the chest, and the second had a ventriculocutaneous fistula. Early operation with removal of the foreign body is warranted in this major complication of a ventricular aneurysmectomy.