The Basis of the Structure and Choice of the Parameters of a Simulator of a Pulsed Fission Chamber
The choice of such parameters of the generator as the resolving power and the number of digits of the code-interval converter is validated by analyzing the instrumental errors as it applied to the specific structure of a Poisson process generator.[PUBLICATION ABSTRACT]