A Distal Fluted, Proximal Modular Femoral Prosthesis in Revision Hip Arthroplasty
Abstract Most reports on the use of modular femoral stems during revision surgery have involved short follow-up periods. The authors evaluated the clinical and radiographic performance of 59 patients fitted with a distal fix modular stem. The average follow-up period was 8.2 years. Average Harris hi...
Gespeichert in:
Veröffentlicht in: | The Journal of arthroplasty 2010-09, Vol.25 (6), p.932-938 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract Most reports on the use of modular femoral stems during revision surgery have involved short follow-up periods. The authors evaluated the clinical and radiographic performance of 59 patients fitted with a distal fix modular stem. The average follow-up period was 8.2 years. Average Harris hip score was improved from 47 to 87.6. Of 19 patients with trochanteric osteotomy, 4 had a displaced greater trochanter. Re-revision was performed in 5 patients, and 3 of these were for subsidence (of these 3, subsidence was associated with dissociation of the coupling part in 1 and with osteotomy nonunion in other 2 [proximal component only]). Modular distally fixed femoral stems were found to offer intraoperative flexibility, but to suffer from subsidence and intraoperative greater trochanter and metaphyseal femoral fractures. |
---|---|
ISSN: | 0883-5403 1532-8406 |
DOI: | 10.1016/j.arth.2009.06.031 |