Extracorporeal perfusion for acute respiratory failure: recent experience with the spiral coil membrane lung

Selection criteria, clinical data, and physiological measurements obtained during five extracorporeal membrane lung perfusions for acute respiratory insufficiency are presented. Four patients died and 1 survived. A new technique of femoral artery cannulation to allow aortic arch perfusion is describ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of thoracic and cardiovascular surgery 1975-03, Vol.69 (3), p.439-449
Hauptverfasser: Zapol, WM, Qvist, J, Pontoppidan, H, Liland, A, McEnany, T, Laver, MB
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Selection criteria, clinical data, and physiological measurements obtained during five extracorporeal membrane lung perfusions for acute respiratory insufficiency are presented. Four patients died and 1 survived. A new technique of femoral artery cannulation to allow aortic arch perfusion is described. When properly monitored, this route provides improved oxygen delivery to the brain during venoarterial (VA) perfusion. The importance of monitoring the equivalent of carotid artery Po2 during VA perfusion is emphasized. Recognition of the effects of high cardiac output in limiting the quality of extracorporeal perfusion, plus the use of hypothermia to reduce output, are stressed. We have confirmed that perfusion can be accomplished with small quantities of heparin, so that bleeding is reduced, but thrombocytopenia and occasional hemorrhage continue to be persistent problems.
ISSN:0022-5223
1097-685X