Hemodynamic Effects of Anemia with and without Plasma Volume Expansion

Hypervolemic anemia and normovolemic anemia were produced in dogs. Cardiac outputs increased comparably with similar degrees of anemia in the hypervolemic and normovolemic animals. No significant association between right atrial mean pressure and cardiac output was found. Right atrial and pulmonary...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Circulation research 1956-05, Vol.4 (3), p.319-324
Hauptverfasser: Fowler, Noble O, Franch, Robert H, Bloom, Walter L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Hypervolemic anemia and normovolemic anemia were produced in dogs. Cardiac outputs increased comparably with similar degrees of anemia in the hypervolemic and normovolemic animals. No significant association between right atrial mean pressure and cardiac output was found. Right atrial and pulmonary arterial pressures increased in a degree comparable to blood volume increase. Systemic mean pressures did not change significantly; there was a significant decrease in total peripheral resistance. The results are consistent with the concept that the increase in cardiac output occurring with hypervolemic anemia is related primarily to the anemia and not to the increase in blood volume.
ISSN:0009-7330
1524-4571
DOI:10.1161/01.RES.4.3.319