A Clinical Evaluation of the RNCA Study Using Fourier Filtering as a Preprocessing Method

Forty-one patients (25 male, 16 female) were studied by RNCA in our institution. There were 42 rest studies and 24 stress studies (66 studies total). Sixteen patients were normal, 15 had ASHD, seven had a cardiomyopathy, and three had left-sided valvular regurgitation. Each study was preprocessed us...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clin. Nucl. Med.; (United States) 1984-06, Vol.9 (6), p.324-331
Hauptverfasser: ROBESON, WILLIAM, ALCAN, KARL E, GRAHAM, MARTIN C, PALESTRO, CHRISTOPHER, OLIVER, FRANCIS H, BENUA, RICHARD S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Forty-one patients (25 male, 16 female) were studied by RNCA in our institution. There were 42 rest studies and 24 stress studies (66 studies total). Sixteen patients were normal, 15 had ASHD, seven had a cardiomyopathy, and three had left-sided valvular regurgitation. Each study was preprocessed using both the standard nine-point smoothing method and Fourier filtering. Amplitude and phase images were also generated. Both preprocessing methods were compared with respect to image quality, border definition, reliability and reproducibility of the LVEF, and cine wall motion interpretation. Image quality and border definition were judged superior by the consensus of two independent observers in 65 of 66 studies (98%) using Fourier filtered data. The LVEF differed between the two processes by greater than .05 in 17 of 66 studies (26%) including five studies in which the LVEF could not be determined using nine-point smoothed data. LV wall motion was normal by both techniques in all control patients by cine analysis. However, cine wall motion analysis using Fourier filtered data demonstrated additional abnormalities in 17 of 25 studies (68%) in the ASHD group, including three uninterpretable studies using nine-point smoothed data. In the cardiomyopathy/valvular heart disease group, ten of 18 studies (56%)had additional wall motion abnormalities sing Fourier filtered data (including four uninterpretable studies using nine-point smoothed data). We conclude that Fourier filtering is superior to the nine-point smooth preprocessing method now in general use in terms of image quality, border definition, generation of an LVEF, and cine wall motion analysis. The advent of the array processor makes routine preprocessing by Fourier filtering a feasible technologic advance in the development of the RNCA study.
ISSN:0363-9762
1536-0229
DOI:10.1097/00003072-198406000-00004