Transport of gases in high-frequency ventilation

We found that the transport of gases in oscillating gas columns was proportional to oscillation frequency and the square of oscillation amplitude. When these results were applied to high-frequency oscillation and high-frequency jet ventilation in dogs, alveolar ventilation was proportional to freque...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Critical care medicine 1984-09, Vol.12 (9), p.708-710
Hauptverfasser: JAEGER, MARC J, KURZWEG, ULRICH H, BANNER, MICHAEL J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We found that the transport of gases in oscillating gas columns was proportional to oscillation frequency and the square of oscillation amplitude. When these results were applied to high-frequency oscillation and high-frequency jet ventilation in dogs, alveolar ventilation was proportional to frequency and to the square of tidal volume, and inversely proportional to anatomic dead space.