Intermittent ventricular parasystole due to entrance block failure

An interaction between three pacemakers (one artificial) has made possible a number of observations on the nature of intermittent parasystole. Evidence shows that the intermittency is due to temporary failure of entrance block. The fixed coupling of the first beat of an intermittent series is observ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Circulation (New York, N.Y.) N.Y.), 1971-09, Vol.44 (3), p.442-445
1. Verfasser: Steffens, T G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An interaction between three pacemakers (one artificial) has made possible a number of observations on the nature of intermittent parasystole. Evidence shows that the intermittency is due to temporary failure of entrance block. The fixed coupling of the first beat of an intermittent series is observed to be a consequence of temporary entrance block failure rather than a manifestation of a more complex mechanism. The records also demonstrate that the reason for failure of the entrance block may be due to preferential penetration of the parasystolic focus early in its diastole.
ISSN:0009-7322
1524-4539
DOI:10.1161/01.CIR.44.3.442