Ozone produced by corona discharge in the presence of water

Significant levels of ozone have been detected in a reaction flask that was designed for studies using negative air ions generated from corona discharge. While diluting the gas in the vessel at the rate of 1.5 liters/min., more than 1.0 ppm O sub(3) was measured in the vessel when grounded water was...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of biometeorology 1984-06, Vol.28 (2), p.157-161
Hauptverfasser: Goheen, S C, Larkin, E C, Bissell, M G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Significant levels of ozone have been detected in a reaction flask that was designed for studies using negative air ions generated from corona discharge. While diluting the gas in the vessel at the rate of 1.5 liters/min., more than 1.0 ppm O sub(3) was measured in the vessel when grounded water was present. Ozone levels were much less (15 ppb) in ambient air near the ion generator. Even in the absence of water, O sub(3) levels were only 7 ppb in the reaction flask. Without the corona discharge apparatus, levels of ozone in the gas phase (with water present) averaged 6 ppb. These results demonstrate that when negative air ions are generated from corona discharge in the presence of water, significant levels of ozone are produced. Therefore, O sub(3) could be directly responsible for many of the oxidizing effects that have been reportedly due to negative air ions.