Ozone produced by corona discharge in the presence of water
Significant levels of ozone have been detected in a reaction flask that was designed for studies using negative air ions generated from corona discharge. While diluting the gas in the vessel at the rate of 1.5 liters/min., more than 1.0 ppm O sub(3) was measured in the vessel when grounded water was...
Gespeichert in:
Veröffentlicht in: | International journal of biometeorology 1984-06, Vol.28 (2), p.157-161 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Significant levels of ozone have been detected in a reaction flask that was designed for studies using negative air ions generated from corona discharge. While diluting the gas in the vessel at the rate of 1.5 liters/min., more than 1.0 ppm O sub(3) was measured in the vessel when grounded water was present. Ozone levels were much less (15 ppb) in ambient air near the ion generator. Even in the absence of water, O sub(3) levels were only 7 ppb in the reaction flask. Without the corona discharge apparatus, levels of ozone in the gas phase (with water present) averaged 6 ppb. These results demonstrate that when negative air ions are generated from corona discharge in the presence of water, significant levels of ozone are produced. Therefore, O sub(3) could be directly responsible for many of the oxidizing effects that have been reportedly due to negative air ions. |
---|---|
ISSN: | 0020-7128 1432-1254 |
DOI: | 10.1007/BF02191728 |