Marginal accuracy of temporary composite crowns

An in vitro study was conducted to quantitatively compare the marginal adaptation of temporary crowns made from Protemp material with those made from Scutan, Provisional, and Trim materials. A direct technique was used to make temporary restorations on prepared teeth with an impression as a matrix....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of prosthetic dentistry 1987-10, Vol.58 (4), p.417-421
Hauptverfasser: Tjan, Anthony H.L., Tjan, Albert H., Grant, Ben E.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An in vitro study was conducted to quantitatively compare the marginal adaptation of temporary crowns made from Protemp material with those made from Scutan, Provisional, and Trim materials. A direct technique was used to make temporary restorations on prepared teeth with an impression as a matrix. Protem, Trim, and Provisional materials produced temporary crowns of comparable accuracy. Crowns made from Scutan material had open margins.
ISSN:0022-3913
1097-6841
DOI:10.1016/0022-3913(87)90266-6