Cardiac Transplantation Following Storage of the Donor Heart by a Portable Hypothermic Perfusion System
Four patients have undergone heterotopic heart transplantation with donor hearts stored by a portable hypothermic perfusion system. Total ischemic periods ranged from 6 hours 55 minutes to 16 hours 50 minutes. One heart, transplanted into a patient who had acutely rejected a previous graft, suffered...
Gespeichert in:
Veröffentlicht in: | The Annals of thoracic surgery 1984-03, Vol.37 (3), p.243-248 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Four patients have undergone heterotopic heart transplantation with donor hearts stored by a portable hypothermic perfusion system. Total ischemic periods ranged from 6 hours 55 minutes to 16 hours 50 minutes. One heart, transplanted into a patient who had acutely rejected a previous graft, suffered accelerated, irreversible, acute rejection within five days, associated with strong antibody formation; donor heart function was never good. In the 3 remaining patients, donor heart function was good after initially being poor for a few hours in 2 patients. One patient died of long-term rejection after 6 months and 1 of tuberculous meningitis after 10 months; 1 remains alive at 15 months.
Neither preservation of the donor heart for periods in excess of approximately 4 hours nor the use of continuous hypothermic perfusion as a method of preservation appears to have been reported previously in the context of the clinical situation. |
---|---|
ISSN: | 0003-4975 1552-6259 |
DOI: | 10.1016/S0003-4975(10)60333-5 |