Four patients have undergone heterotopic heart transplantation with donor hearts stored by a portable hypothermic perfusion system. Total ischemic periods ranged from 6 hours 55 minutes to 16 hours 50 minutes. One heart, transplanted into a patient who had acutely rejected a previous graft, suffered...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 1984-03, Vol.37 (3), p.243-248
Hauptverfasser: Wicomb, W.N., Cooper, D.K.C., Novitzky, D., Barnard, C.N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Four patients have undergone heterotopic heart transplantation with donor hearts stored by a portable hypothermic perfusion system. Total ischemic periods ranged from 6 hours 55 minutes to 16 hours 50 minutes. One heart, transplanted into a patient who had acutely rejected a previous graft, suffered accelerated, irreversible, acute rejection within five days, associated with strong antibody formation; donor heart function was never good. In the 3 remaining patients, donor heart function was good after initially being poor for a few hours in 2 patients. One patient died of long-term rejection after 6 months and 1 of tuberculous meningitis after 10 months; 1 remains alive at 15 months. Neither preservation of the donor heart for periods in excess of approximately 4 hours nor the use of continuous hypothermic perfusion as a method of preservation appears to have been reported previously in the context of the clinical situation.
ISSN:0003-4975
1552-6259
DOI:10.1016/S0003-4975(10)60333-5