Quantification of error in measurement of radial inclination angle and radial-carpal distance

Posteroanterior wrist radiographs of eight patients were evaluated by eight orthopedists. Radial inclination angle and radial-carpal distance were measured by use of a standardized technique. The standard deviation for radial inclination angle was 2 degrees. The standard deviation for radial-carpal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of hand surgery (American ed.) 1991-05, Vol.16 (3), p.399-400
Hauptverfasser: DiBenedetto, Michael R., Lubbers, Lawrence M., Ruff, Michael E., Nappi, James F., Coleman, Carl R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Posteroanterior wrist radiographs of eight patients were evaluated by eight orthopedists. Radial inclination angle and radial-carpal distance were measured by use of a standardized technique. The standard deviation for radial inclination angle was 2 degrees. The standard deviation for radial-carpal distance was 1 mm. The measured rotational variation of radial inclination and radial-carpal distance is 1 degree and 1 mm, respectively, through a 10-degree arc of supination and pronation.