Quantification of error in measurement of radial inclination angle and radial-carpal distance
Posteroanterior wrist radiographs of eight patients were evaluated by eight orthopedists. Radial inclination angle and radial-carpal distance were measured by use of a standardized technique. The standard deviation for radial inclination angle was 2 degrees. The standard deviation for radial-carpal...
Gespeichert in:
Veröffentlicht in: | The Journal of hand surgery (American ed.) 1991-05, Vol.16 (3), p.399-400 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Posteroanterior wrist radiographs of eight patients were evaluated by eight orthopedists. Radial inclination angle and radial-carpal distance were measured by use of a standardized technique. The standard deviation for radial inclination angle was 2 degrees. The standard deviation for radial-carpal distance was 1 mm. The measured rotational variation of radial inclination and radial-carpal distance is 1 degree and 1 mm, respectively, through a 10-degree arc of supination and pronation. |
---|---|
ISSN: | 0363-5023 1531-6564 |
DOI: | 10.1016/0363-5023(91)90004-U |