The high performance liquid chromatographic measurement of chloramphenicol and its succinate esters in serum

We describe a reliable HPLC procedure for the simultaneous measurement of chloramphenicol and its succinate esters in 30 μL of serum or plasma. The procedure has been applied to assess both the optimum dosing regimen and clinical pharmacokinetics in premature infants.