The bead test: a critical appraisal

An evaluation of the visual acuity levels obtained with the candy bead test (Bock) was performed. White beads (1 mm) were placed on a white felt background under controlled illumination. Ten subjects were required to localize randomly placed beads through increased degrees of induced optical blur. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of optometry and physiological optics 1983-03, Vol.60 (3), p.199-203
Hauptverfasser: Richman, J E, Garzia, R P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An evaluation of the visual acuity levels obtained with the candy bead test (Bock) was performed. White beads (1 mm) were placed on a white felt background under controlled illumination. Ten subjects were required to localize randomly placed beads through increased degrees of induced optical blur. The visual acuity was then measured at the blur level yielding 60% accuracy in localization. The results indicate a range of visual acuity from 6/45 to 6/60 (20/150 to 20/200). These findings are significantly worse than the levels of acuity [6/18 to 6/24 (20/60 to 20/80)] found by other authors. Therefore, our findings raise concerns and indicate caution in the clinical interpretation of the bead test.
ISSN:0093-7002