Fabrication of glass microelectrodes with microprocessor control
A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pu...
Gespeichert in:
Veröffentlicht in: | Journal of neuroscience methods 1983-01, Vol.7 (2), p.171-183 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 183 |
---|---|
container_issue | 2 |
container_start_page | 171 |
container_title | Journal of neuroscience methods |
container_volume | 7 |
creator | Bertrand, D. Cand, P. Henauer, R. Bader, C.R. |
description | A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pulling procedure and some of the constraints regarding the current supplied to the heating filament are discussed. |
doi_str_mv | 10.1016/0165-0270(83)90080-8 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80421605</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0165027083900808</els_id><sourcerecordid>13533595</sourcerecordid><originalsourceid>FETCH-LOGICAL-c388t-44c6a13912c83a34ecb992f84e98d43fc010bfd5ad8a88586da2a2c040e7ea293</originalsourceid><addsrcrecordid>eNqFkE1LxDAQhoMouq7-A4WeRA_VSZOmk4so4hcseFHwFrLpVCPdjSZdxX9v6y571EOYMO87Xw9jBxxOOXB11r8yh6KCYxQnGgAhxw024lgVuarweZON1pYdtpvSGwBIDWqbbSuFleJ6xC5u7DR6Zzsf5llospfWppTNvIuBWnJdDDWl7Mt3r8vkewyOUgoxc2Heq-0e22psm2h_Fcfs6eb68eounzzc3l9dTnInELtcSqcsF5oXDoUVktxU66JBSRprKRoHHKZNXdoaLWKJqraFLRxIoIpsocWYHS379ht8LCh1ZuaTo7a1cwqLZBBkwRWU_xq5KIUo9WCUS2N_VkqRGvMe_czGb8PBDITNgM8M-AwK80u4_4zZ4ar_Yjqjel20Qtrr50udehqfnqJJztPcUe1jD9TUwf894AcTxIq3</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>13533595</pqid></control><display><type>article</type><title>Fabrication of glass microelectrodes with microprocessor control</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Bertrand, D. ; Cand, P. ; Henauer, R. ; Bader, C.R.</creator><creatorcontrib>Bertrand, D. ; Cand, P. ; Henauer, R. ; Bader, C.R.</creatorcontrib><description>A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pulling procedure and some of the constraints regarding the current supplied to the heating filament are discussed.</description><identifier>ISSN: 0165-0270</identifier><identifier>EISSN: 1872-678X</identifier><identifier>DOI: 10.1016/0165-0270(83)90080-8</identifier><identifier>PMID: 6687619</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Computers ; electrode puller ; Glass ; Microcomputers ; microelectrode ; Microelectrodes ; micropipette ; microprocessor ; Neurophysiology - instrumentation ; patch clamp ; Software</subject><ispartof>Journal of neuroscience methods, 1983-01, Vol.7 (2), p.171-183</ispartof><rights>1983</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c388t-44c6a13912c83a34ecb992f84e98d43fc010bfd5ad8a88586da2a2c040e7ea293</citedby><cites>FETCH-LOGICAL-c388t-44c6a13912c83a34ecb992f84e98d43fc010bfd5ad8a88586da2a2c040e7ea293</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0165027083900808$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/6687619$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bertrand, D.</creatorcontrib><creatorcontrib>Cand, P.</creatorcontrib><creatorcontrib>Henauer, R.</creatorcontrib><creatorcontrib>Bader, C.R.</creatorcontrib><title>Fabrication of glass microelectrodes with microprocessor control</title><title>Journal of neuroscience methods</title><addtitle>J Neurosci Methods</addtitle><description>A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pulling procedure and some of the constraints regarding the current supplied to the heating filament are discussed.</description><subject>Computers</subject><subject>electrode puller</subject><subject>Glass</subject><subject>Microcomputers</subject><subject>microelectrode</subject><subject>Microelectrodes</subject><subject>micropipette</subject><subject>microprocessor</subject><subject>Neurophysiology - instrumentation</subject><subject>patch clamp</subject><subject>Software</subject><issn>0165-0270</issn><issn>1872-678X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1983</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1LxDAQhoMouq7-A4WeRA_VSZOmk4so4hcseFHwFrLpVCPdjSZdxX9v6y571EOYMO87Xw9jBxxOOXB11r8yh6KCYxQnGgAhxw024lgVuarweZON1pYdtpvSGwBIDWqbbSuFleJ6xC5u7DR6Zzsf5llospfWppTNvIuBWnJdDDWl7Mt3r8vkewyOUgoxc2Heq-0e22psm2h_Fcfs6eb68eounzzc3l9dTnInELtcSqcsF5oXDoUVktxU66JBSRprKRoHHKZNXdoaLWKJqraFLRxIoIpsocWYHS379ht8LCh1ZuaTo7a1cwqLZBBkwRWU_xq5KIUo9WCUS2N_VkqRGvMe_czGb8PBDITNgM8M-AwK80u4_4zZ4ar_Yjqjel20Qtrr50udehqfnqJJztPcUe1jD9TUwf894AcTxIq3</recordid><startdate>19830101</startdate><enddate>19830101</enddate><creator>Bertrand, D.</creator><creator>Cand, P.</creator><creator>Henauer, R.</creator><creator>Bader, C.R.</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TK</scope><scope>7X8</scope></search><sort><creationdate>19830101</creationdate><title>Fabrication of glass microelectrodes with microprocessor control</title><author>Bertrand, D. ; Cand, P. ; Henauer, R. ; Bader, C.R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c388t-44c6a13912c83a34ecb992f84e98d43fc010bfd5ad8a88586da2a2c040e7ea293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1983</creationdate><topic>Computers</topic><topic>electrode puller</topic><topic>Glass</topic><topic>Microcomputers</topic><topic>microelectrode</topic><topic>Microelectrodes</topic><topic>micropipette</topic><topic>microprocessor</topic><topic>Neurophysiology - instrumentation</topic><topic>patch clamp</topic><topic>Software</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bertrand, D.</creatorcontrib><creatorcontrib>Cand, P.</creatorcontrib><creatorcontrib>Henauer, R.</creatorcontrib><creatorcontrib>Bader, C.R.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Neurosciences Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of neuroscience methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bertrand, D.</au><au>Cand, P.</au><au>Henauer, R.</au><au>Bader, C.R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fabrication of glass microelectrodes with microprocessor control</atitle><jtitle>Journal of neuroscience methods</jtitle><addtitle>J Neurosci Methods</addtitle><date>1983-01-01</date><risdate>1983</risdate><volume>7</volume><issue>2</issue><spage>171</spage><epage>183</epage><pages>171-183</pages><issn>0165-0270</issn><eissn>1872-678X</eissn><abstract>A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pulling procedure and some of the constraints regarding the current supplied to the heating filament are discussed.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>6687619</pmid><doi>10.1016/0165-0270(83)90080-8</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0165-0270 |
ispartof | Journal of neuroscience methods, 1983-01, Vol.7 (2), p.171-183 |
issn | 0165-0270 1872-678X |
language | eng |
recordid | cdi_proquest_miscellaneous_80421605 |
source | MEDLINE; Elsevier ScienceDirect Journals Complete |
subjects | Computers electrode puller Glass Microcomputers microelectrode Microelectrodes micropipette microprocessor Neurophysiology - instrumentation patch clamp Software |
title | Fabrication of glass microelectrodes with microprocessor control |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T20%3A37%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fabrication%20of%20glass%20microelectrodes%20with%20microprocessor%20control&rft.jtitle=Journal%20of%20neuroscience%20methods&rft.au=Bertrand,%20D.&rft.date=1983-01-01&rft.volume=7&rft.issue=2&rft.spage=171&rft.epage=183&rft.pages=171-183&rft.issn=0165-0270&rft.eissn=1872-678X&rft_id=info:doi/10.1016/0165-0270(83)90080-8&rft_dat=%3Cproquest_cross%3E13533595%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=13533595&rft_id=info:pmid/6687619&rft_els_id=0165027083900808&rfr_iscdi=true |