Fabrication of glass microelectrodes with microprocessor control

A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of neuroscience methods 1983-01, Vol.7 (2), p.171-183
Hauptverfasser: Bertrand, D., Cand, P., Henauer, R., Bader, C.R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 183
container_issue 2
container_start_page 171
container_title Journal of neuroscience methods
container_volume 7
creator Bertrand, D.
Cand, P.
Henauer, R.
Bader, C.R.
description A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pulling procedure and some of the constraints regarding the current supplied to the heating filament are discussed.
doi_str_mv 10.1016/0165-0270(83)90080-8
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80421605</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0165027083900808</els_id><sourcerecordid>13533595</sourcerecordid><originalsourceid>FETCH-LOGICAL-c388t-44c6a13912c83a34ecb992f84e98d43fc010bfd5ad8a88586da2a2c040e7ea293</originalsourceid><addsrcrecordid>eNqFkE1LxDAQhoMouq7-A4WeRA_VSZOmk4so4hcseFHwFrLpVCPdjSZdxX9v6y571EOYMO87Xw9jBxxOOXB11r8yh6KCYxQnGgAhxw024lgVuarweZON1pYdtpvSGwBIDWqbbSuFleJ6xC5u7DR6Zzsf5llospfWppTNvIuBWnJdDDWl7Mt3r8vkewyOUgoxc2Heq-0e22psm2h_Fcfs6eb68eounzzc3l9dTnInELtcSqcsF5oXDoUVktxU66JBSRprKRoHHKZNXdoaLWKJqraFLRxIoIpsocWYHS379ht8LCh1ZuaTo7a1cwqLZBBkwRWU_xq5KIUo9WCUS2N_VkqRGvMe_czGb8PBDITNgM8M-AwK80u4_4zZ4ar_Yjqjel20Qtrr50udehqfnqJJztPcUe1jD9TUwf894AcTxIq3</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>13533595</pqid></control><display><type>article</type><title>Fabrication of glass microelectrodes with microprocessor control</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals Complete</source><creator>Bertrand, D. ; Cand, P. ; Henauer, R. ; Bader, C.R.</creator><creatorcontrib>Bertrand, D. ; Cand, P. ; Henauer, R. ; Bader, C.R.</creatorcontrib><description>A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pulling procedure and some of the constraints regarding the current supplied to the heating filament are discussed.</description><identifier>ISSN: 0165-0270</identifier><identifier>EISSN: 1872-678X</identifier><identifier>DOI: 10.1016/0165-0270(83)90080-8</identifier><identifier>PMID: 6687619</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Computers ; electrode puller ; Glass ; Microcomputers ; microelectrode ; Microelectrodes ; micropipette ; microprocessor ; Neurophysiology - instrumentation ; patch clamp ; Software</subject><ispartof>Journal of neuroscience methods, 1983-01, Vol.7 (2), p.171-183</ispartof><rights>1983</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c388t-44c6a13912c83a34ecb992f84e98d43fc010bfd5ad8a88586da2a2c040e7ea293</citedby><cites>FETCH-LOGICAL-c388t-44c6a13912c83a34ecb992f84e98d43fc010bfd5ad8a88586da2a2c040e7ea293</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0165027083900808$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/6687619$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bertrand, D.</creatorcontrib><creatorcontrib>Cand, P.</creatorcontrib><creatorcontrib>Henauer, R.</creatorcontrib><creatorcontrib>Bader, C.R.</creatorcontrib><title>Fabrication of glass microelectrodes with microprocessor control</title><title>Journal of neuroscience methods</title><addtitle>J Neurosci Methods</addtitle><description>A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pulling procedure and some of the constraints regarding the current supplied to the heating filament are discussed.</description><subject>Computers</subject><subject>electrode puller</subject><subject>Glass</subject><subject>Microcomputers</subject><subject>microelectrode</subject><subject>Microelectrodes</subject><subject>micropipette</subject><subject>microprocessor</subject><subject>Neurophysiology - instrumentation</subject><subject>patch clamp</subject><subject>Software</subject><issn>0165-0270</issn><issn>1872-678X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1983</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1LxDAQhoMouq7-A4WeRA_VSZOmk4so4hcseFHwFrLpVCPdjSZdxX9v6y571EOYMO87Xw9jBxxOOXB11r8yh6KCYxQnGgAhxw024lgVuarweZON1pYdtpvSGwBIDWqbbSuFleJ6xC5u7DR6Zzsf5llospfWppTNvIuBWnJdDDWl7Mt3r8vkewyOUgoxc2Heq-0e22psm2h_Fcfs6eb68eounzzc3l9dTnInELtcSqcsF5oXDoUVktxU66JBSRprKRoHHKZNXdoaLWKJqraFLRxIoIpsocWYHS379ht8LCh1ZuaTo7a1cwqLZBBkwRWU_xq5KIUo9WCUS2N_VkqRGvMe_czGb8PBDITNgM8M-AwK80u4_4zZ4ar_Yjqjel20Qtrr50udehqfnqJJztPcUe1jD9TUwf894AcTxIq3</recordid><startdate>19830101</startdate><enddate>19830101</enddate><creator>Bertrand, D.</creator><creator>Cand, P.</creator><creator>Henauer, R.</creator><creator>Bader, C.R.</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TK</scope><scope>7X8</scope></search><sort><creationdate>19830101</creationdate><title>Fabrication of glass microelectrodes with microprocessor control</title><author>Bertrand, D. ; Cand, P. ; Henauer, R. ; Bader, C.R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c388t-44c6a13912c83a34ecb992f84e98d43fc010bfd5ad8a88586da2a2c040e7ea293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1983</creationdate><topic>Computers</topic><topic>electrode puller</topic><topic>Glass</topic><topic>Microcomputers</topic><topic>microelectrode</topic><topic>Microelectrodes</topic><topic>micropipette</topic><topic>microprocessor</topic><topic>Neurophysiology - instrumentation</topic><topic>patch clamp</topic><topic>Software</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bertrand, D.</creatorcontrib><creatorcontrib>Cand, P.</creatorcontrib><creatorcontrib>Henauer, R.</creatorcontrib><creatorcontrib>Bader, C.R.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Neurosciences Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of neuroscience methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bertrand, D.</au><au>Cand, P.</au><au>Henauer, R.</au><au>Bader, C.R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fabrication of glass microelectrodes with microprocessor control</atitle><jtitle>Journal of neuroscience methods</jtitle><addtitle>J Neurosci Methods</addtitle><date>1983-01-01</date><risdate>1983</risdate><volume>7</volume><issue>2</issue><spage>171</spage><epage>183</epage><pages>171-183</pages><issn>0165-0270</issn><eissn>1872-678X</eissn><abstract>A microelectrode puller is described for the fabrication of a variety of microelectrodes such as fine tip electrodes or patch clamp electrodes. Microprocessor control permits rapid switching from one type of electrode pulling configuration to another. The motion of the puller during the electrode pulling procedure and some of the constraints regarding the current supplied to the heating filament are discussed.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>6687619</pmid><doi>10.1016/0165-0270(83)90080-8</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0165-0270
ispartof Journal of neuroscience methods, 1983-01, Vol.7 (2), p.171-183
issn 0165-0270
1872-678X
language eng
recordid cdi_proquest_miscellaneous_80421605
source MEDLINE; Elsevier ScienceDirect Journals Complete
subjects Computers
electrode puller
Glass
Microcomputers
microelectrode
Microelectrodes
micropipette
microprocessor
Neurophysiology - instrumentation
patch clamp
Software
title Fabrication of glass microelectrodes with microprocessor control
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T20%3A37%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fabrication%20of%20glass%20microelectrodes%20with%20microprocessor%20control&rft.jtitle=Journal%20of%20neuroscience%20methods&rft.au=Bertrand,%20D.&rft.date=1983-01-01&rft.volume=7&rft.issue=2&rft.spage=171&rft.epage=183&rft.pages=171-183&rft.issn=0165-0270&rft.eissn=1872-678X&rft_id=info:doi/10.1016/0165-0270(83)90080-8&rft_dat=%3Cproquest_cross%3E13533595%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=13533595&rft_id=info:pmid/6687619&rft_els_id=0165027083900808&rfr_iscdi=true