Use of the 82Sr/ 82Rb Generator in Clinical PET Studies

The use of the 82Sr/ 82Rb generator in clinical positron emission tomography (PET) studies of myocardial perfusion has been described. An infusion pump is used to deliver the short-lived 82Rb from the generator to the patient. Various characteristics of the generator and the infusion system are desc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology Nuclear medicine and biology, 1990, Vol.17 (8), p.763,767-765,768
Hauptverfasser: Saha, Gopal B., Go, Raymundo T., Macintyre, William J., Marwick, Thomas H., Beachler, Annette, King, Janet L., Neumann, Donald R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 765,768
container_issue 8
container_start_page 763,767
container_title International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology
container_volume 17
creator Saha, Gopal B.
Go, Raymundo T.
Macintyre, William J.
Marwick, Thomas H.
Beachler, Annette
King, Janet L.
Neumann, Donald R.
description The use of the 82Sr/ 82Rb generator in clinical positron emission tomography (PET) studies of myocardial perfusion has been described. An infusion pump is used to deliver the short-lived 82Rb from the generator to the patient. Various characteristics of the generator and the infusion system are described. The 82Rb yield was 69.8 ± 13.3% and the 82Sr breakthrough was always less than the limit of 0.02 μCi/mCi 82Rb. The yield of 82Rb increased with the flow rate and the potency of the generator. Patients with coronary artery disease were studied for myocardial perfusion abnormalities by the 82Rb PET technique and images of excellent diagnostic quality were obtained.
doi_str_mv 10.1016/0883-2897(90)90023-T
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80296943</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>088328979090023T</els_id><sourcerecordid>80296943</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2333-5fa8508360b2833dfe948714bc3ae4a7d0727593f405250f766c9f1ad3e685f73</originalsourceid><addsrcrecordid>eNp9kFFLwzAQx_OgzDn9Bgp9ENGHujRJm-RFkDGnMFBc9xzS9IKRrtWkFfz2Zm7s0Zc7uP_vjuOH0EWG7zKcFVMsBE2JkPxG4luJMaFpeYTGh_EJOg3hI84Fy_kIjQjmkhE6RnwdIOls0r9DIsjKT2N9q5IFtOB13_nEtcmsca0zukle52Wy6ofaQThDx1Y3Ac73fYLWj_Ny9pQuXxbPs4dlagilNM2tFjkWtMAVEZTWFiQTPGOVoRqY5jXmhOeSWoZzkmPLi8JIm-maQiFyy-kEXe_ufvrua4DQq40LBppGt9ANQQlMZCEZjSDbgcZ3IXiw6tO7jfY_KsNq60htZaitDCWx-nOkyrh2ub8_VBuoD0t7QTG_2uc6RAXW69a4cMAYE0wKGbH7HQbRxbcDr4Jx0BqonQfTq7pz___xC320gJg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80296943</pqid></control><display><type>article</type><title>Use of the 82Sr/ 82Rb Generator in Clinical PET Studies</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Saha, Gopal B. ; Go, Raymundo T. ; Macintyre, William J. ; Marwick, Thomas H. ; Beachler, Annette ; King, Janet L. ; Neumann, Donald R.</creator><creatorcontrib>Saha, Gopal B. ; Go, Raymundo T. ; Macintyre, William J. ; Marwick, Thomas H. ; Beachler, Annette ; King, Janet L. ; Neumann, Donald R.</creatorcontrib><description>The use of the 82Sr/ 82Rb generator in clinical positron emission tomography (PET) studies of myocardial perfusion has been described. An infusion pump is used to deliver the short-lived 82Rb from the generator to the patient. Various characteristics of the generator and the infusion system are described. The 82Rb yield was 69.8 ± 13.3% and the 82Sr breakthrough was always less than the limit of 0.02 μCi/mCi 82Rb. The yield of 82Rb increased with the flow rate and the potency of the generator. Patients with coronary artery disease were studied for myocardial perfusion abnormalities by the 82Rb PET technique and images of excellent diagnostic quality were obtained.</description><identifier>ISSN: 0883-2897</identifier><identifier>DOI: 10.1016/0883-2897(90)90023-T</identifier><identifier>PMID: 2079423</identifier><identifier>CODEN: NMBIEO</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Biological and medical sciences ; Coronary Circulation ; Coronary Disease - diagnostic imaging ; Coronary Disease - physiopathology ; Humans ; Infusion Pumps ; Investigative techniques, diagnostic techniques (general aspects) ; Medical sciences ; Miscellaneous. Technology ; Radionuclide Generators ; Radionuclide investigations ; Rubidium Radioisotopes - administration &amp; dosage ; Tomography, Emission-Computed</subject><ispartof>International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology, 1990, Vol.17 (8), p.763,767-765,768</ispartof><rights>1990</rights><rights>1993 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2333-5fa8508360b2833dfe948714bc3ae4a7d0727593f405250f766c9f1ad3e685f73</citedby><cites>FETCH-LOGICAL-c2333-5fa8508360b2833dfe948714bc3ae4a7d0727593f405250f766c9f1ad3e685f73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,4012,27912,27913,27914</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4484989$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2079423$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Saha, Gopal B.</creatorcontrib><creatorcontrib>Go, Raymundo T.</creatorcontrib><creatorcontrib>Macintyre, William J.</creatorcontrib><creatorcontrib>Marwick, Thomas H.</creatorcontrib><creatorcontrib>Beachler, Annette</creatorcontrib><creatorcontrib>King, Janet L.</creatorcontrib><creatorcontrib>Neumann, Donald R.</creatorcontrib><title>Use of the 82Sr/ 82Rb Generator in Clinical PET Studies</title><title>International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology</title><addtitle>Int J Rad Appl Instrum B</addtitle><description>The use of the 82Sr/ 82Rb generator in clinical positron emission tomography (PET) studies of myocardial perfusion has been described. An infusion pump is used to deliver the short-lived 82Rb from the generator to the patient. Various characteristics of the generator and the infusion system are described. The 82Rb yield was 69.8 ± 13.3% and the 82Sr breakthrough was always less than the limit of 0.02 μCi/mCi 82Rb. The yield of 82Rb increased with the flow rate and the potency of the generator. Patients with coronary artery disease were studied for myocardial perfusion abnormalities by the 82Rb PET technique and images of excellent diagnostic quality were obtained.</description><subject>Biological and medical sciences</subject><subject>Coronary Circulation</subject><subject>Coronary Disease - diagnostic imaging</subject><subject>Coronary Disease - physiopathology</subject><subject>Humans</subject><subject>Infusion Pumps</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Medical sciences</subject><subject>Miscellaneous. Technology</subject><subject>Radionuclide Generators</subject><subject>Radionuclide investigations</subject><subject>Rubidium Radioisotopes - administration &amp; dosage</subject><subject>Tomography, Emission-Computed</subject><issn>0883-2897</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kFFLwzAQx_OgzDn9Bgp9ENGHujRJm-RFkDGnMFBc9xzS9IKRrtWkFfz2Zm7s0Zc7uP_vjuOH0EWG7zKcFVMsBE2JkPxG4luJMaFpeYTGh_EJOg3hI84Fy_kIjQjmkhE6RnwdIOls0r9DIsjKT2N9q5IFtOB13_nEtcmsca0zukle52Wy6ofaQThDx1Y3Ac73fYLWj_Ny9pQuXxbPs4dlagilNM2tFjkWtMAVEZTWFiQTPGOVoRqY5jXmhOeSWoZzkmPLi8JIm-maQiFyy-kEXe_ufvrua4DQq40LBppGt9ANQQlMZCEZjSDbgcZ3IXiw6tO7jfY_KsNq60htZaitDCWx-nOkyrh2ub8_VBuoD0t7QTG_2uc6RAXW69a4cMAYE0wKGbH7HQbRxbcDr4Jx0BqonQfTq7pz___xC320gJg</recordid><startdate>1990</startdate><enddate>1990</enddate><creator>Saha, Gopal B.</creator><creator>Go, Raymundo T.</creator><creator>Macintyre, William J.</creator><creator>Marwick, Thomas H.</creator><creator>Beachler, Annette</creator><creator>King, Janet L.</creator><creator>Neumann, Donald R.</creator><general>Elsevier Ltd</general><general>Pergamon</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1990</creationdate><title>Use of the 82Sr/ 82Rb Generator in Clinical PET Studies</title><author>Saha, Gopal B. ; Go, Raymundo T. ; Macintyre, William J. ; Marwick, Thomas H. ; Beachler, Annette ; King, Janet L. ; Neumann, Donald R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2333-5fa8508360b2833dfe948714bc3ae4a7d0727593f405250f766c9f1ad3e685f73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Biological and medical sciences</topic><topic>Coronary Circulation</topic><topic>Coronary Disease - diagnostic imaging</topic><topic>Coronary Disease - physiopathology</topic><topic>Humans</topic><topic>Infusion Pumps</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Medical sciences</topic><topic>Miscellaneous. Technology</topic><topic>Radionuclide Generators</topic><topic>Radionuclide investigations</topic><topic>Rubidium Radioisotopes - administration &amp; dosage</topic><topic>Tomography, Emission-Computed</topic><toplevel>online_resources</toplevel><creatorcontrib>Saha, Gopal B.</creatorcontrib><creatorcontrib>Go, Raymundo T.</creatorcontrib><creatorcontrib>Macintyre, William J.</creatorcontrib><creatorcontrib>Marwick, Thomas H.</creatorcontrib><creatorcontrib>Beachler, Annette</creatorcontrib><creatorcontrib>King, Janet L.</creatorcontrib><creatorcontrib>Neumann, Donald R.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Saha, Gopal B.</au><au>Go, Raymundo T.</au><au>Macintyre, William J.</au><au>Marwick, Thomas H.</au><au>Beachler, Annette</au><au>King, Janet L.</au><au>Neumann, Donald R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Use of the 82Sr/ 82Rb Generator in Clinical PET Studies</atitle><jtitle>International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology</jtitle><addtitle>Int J Rad Appl Instrum B</addtitle><date>1990</date><risdate>1990</risdate><volume>17</volume><issue>8</issue><spage>763,767</spage><epage>765,768</epage><pages>763,767-765,768</pages><issn>0883-2897</issn><coden>NMBIEO</coden><abstract>The use of the 82Sr/ 82Rb generator in clinical positron emission tomography (PET) studies of myocardial perfusion has been described. An infusion pump is used to deliver the short-lived 82Rb from the generator to the patient. Various characteristics of the generator and the infusion system are described. The 82Rb yield was 69.8 ± 13.3% and the 82Sr breakthrough was always less than the limit of 0.02 μCi/mCi 82Rb. The yield of 82Rb increased with the flow rate and the potency of the generator. Patients with coronary artery disease were studied for myocardial perfusion abnormalities by the 82Rb PET technique and images of excellent diagnostic quality were obtained.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><pmid>2079423</pmid><doi>10.1016/0883-2897(90)90023-T</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0883-2897
ispartof International journal of radiation applications and instrumentation. Part B, Nuclear medicine and biology, 1990, Vol.17 (8), p.763,767-765,768
issn 0883-2897
language eng
recordid cdi_proquest_miscellaneous_80296943
source MEDLINE; Alma/SFX Local Collection
subjects Biological and medical sciences
Coronary Circulation
Coronary Disease - diagnostic imaging
Coronary Disease - physiopathology
Humans
Infusion Pumps
Investigative techniques, diagnostic techniques (general aspects)
Medical sciences
Miscellaneous. Technology
Radionuclide Generators
Radionuclide investigations
Rubidium Radioisotopes - administration & dosage
Tomography, Emission-Computed
title Use of the 82Sr/ 82Rb Generator in Clinical PET Studies
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T09%3A43%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Use%20of%20the%2082Sr/%2082Rb%20Generator%20in%20Clinical%20PET%20Studies&rft.jtitle=International%20journal%20of%20radiation%20applications%20and%20instrumentation.%20Part%20B,%20Nuclear%20medicine%20and%20biology&rft.au=Saha,%20Gopal%20B.&rft.date=1990&rft.volume=17&rft.issue=8&rft.spage=763,767&rft.epage=765,768&rft.pages=763,767-765,768&rft.issn=0883-2897&rft.coden=NMBIEO&rft_id=info:doi/10.1016/0883-2897(90)90023-T&rft_dat=%3Cproquest_cross%3E80296943%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=80296943&rft_id=info:pmid/2079423&rft_els_id=088328979090023T&rfr_iscdi=true