Determination of Glutathione, D-Penicillamine using a High Performance Liquid Chromatography with a Voltammetric Detector
A method for the simultaneous determination of glutathione and D-penicillamine in the human blood was developed by use of a high-performance liquid chromatography with a voltammetric detector. The glutathione and D-penicillamine values in the blood of patients with rheumatoid arthritis treated with...
Gespeichert in:
Veröffentlicht in: | YAKUGAKU ZASSHI 1982/07/25, Vol.102(7), pp.659-665 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | jpn |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A method for the simultaneous determination of glutathione and D-penicillamine in the human blood was developed by use of a high-performance liquid chromatography with a voltammetric detector. The glutathione and D-penicillamine values in the blood of patients with rheumatoid arthritis treated with D-penicillamine (100-300 mg/d) were studied. It was found that the glutathione values in the blood of responders to D-penicillamine (10 patients) were 25% higher than that of non-responders (10 patients) (p |
---|---|
ISSN: | 0031-6903 1347-5231 |
DOI: | 10.1248/yakushi1947.102.7_659 |