Evaluation of contact versus non-contact diode laser cyclophotocoagulation for refractory glaucomas using similar energy settings
Purpose: To compare the efficacy of contact and non‐contact techniques of diode transscleral cyclophotocoagulation (TSCPC) in patients with refractory glaucoma in a prospective randomized manner. Methods: Sixty eyes with refractory glaucoma were randomly treated with either the contact or non‐contac...
Gespeichert in:
Veröffentlicht in: | Clinical & experimental ophthalmology 2004-02, Vol.32 (1), p.33-38 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: To compare the efficacy of contact and non‐contact techniques of diode transscleral cyclophotocoagulation (TSCPC) in patients with refractory glaucoma in a prospective randomized manner.
Methods: Sixty eyes with refractory glaucoma were randomly treated with either the contact or non‐contact technique of diode TSCPC and followed up for a minimum of 12 months. A standard protocol of 1500 mW for 2 s per spot, with 40 spots over the entire 360° circumference was followed for all eyes in both groups.
Results: The reduction of mean baseline intraocular pressure (IOP) from 44.5 ± 7.4 mmHg to 14.8 ± 1.8 mmHg with the contact mode was not significantly different from that in the non‐contact mode of 41.9 ± 8.8 mmHg reduced to 14.5 ± 1.5 mmHg (P = 0.34). The probability of IOP survival ( |
---|---|
ISSN: | 1442-6404 1442-9071 |
DOI: | 10.1046/j.1442-9071.2004.00754.x |