Circadian Rhythms in Two Types of Anaerobic Cycle Leg Exercise: Force-Velocity and 30-s Wingate Tests

Abstract Previous studies investigating the impact of circadian rhythms on performance during anaerobic cycle leg exercise have yielded conflicting results. The purpose of the present investigation was firstly, to determine the effect of the time of day on anaerobic performance during a force-veloci...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of sports medicine 2004, Vol.25 (1), p.14-19
Hauptverfasser: Souissi, N., Gauthier, A., Sesboüé, B., Larue, J., Davenne, D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Previous studies investigating the impact of circadian rhythms on performance during anaerobic cycle leg exercise have yielded conflicting results. The purpose of the present investigation was firstly, to determine the effect of the time of day on anaerobic performance during a force-velocity test on a cycle ergometer (F-V) and the Wingate test and secondly, to relate any changes in anaerobic performance to the circadian rhythm in oral temperature. Nineteen subjects volunteered to take part in the study. In a balanced and randomized study design, subjects were measured for maximal power (P max ) (force-velocity test), peak power (P peak ) and mean power (P mean ) (Wingate test) on six separate occasions. These were at 02 : 00, 06 : 00, 10 : 00, 14 : 00, 18 : 00 and 22 : 00 hours on separate days. There was an interval of 28 h between two successive tests. Oral temperature and body mass were measured before each test. Body mass did not vary during the day but a significant time of day effect was observed for the oral temperature with an acrophase at 18 : 22 ± 00 : 34 hours. A significant circadian rhythm was found for P max with an acrophase at 17 : 10 ± 00 : 52 hours and an amplitude of 7 %. A time-of-day effect was significant for F 0 and V 0 . Also a significant circadian rhythm was observed for P peak with an acrophase at 17 : 24 ± 00 : 36 hours and an amplitude of 7.6 % and for P mean with an acrophase at 18 : 00 ± 01 : 01 hours and an amplitude of 11.3 %. The results indicated that oral temperature, P peak , P mean and P max varied concomitantly during the day. These results suggest that there was a circadian rhythm in anaerobic performance during cycle tests. The recording of oral temperature allows one to estimate the time of occurrence of maximal and minimal values in the circadian rhythm of anaerobic performance.
ISSN:0172-4622
1439-3964
DOI:10.1055/s-2003-45226