Electrochemical determination of oxytetracycline in veterinary drugs

Conductometric, potentiometric and cyclic voltammetric (CV) titration methods are proposed for determination of oxytetracycline (OTC), commonly used in veterinary. The electrochemical titration of OTC hydrochloride with NH 4Mo 7O 24, NaVO 3, NaOH, AgNO 3 and FeCl 3 as titrants are reported. The prop...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical and biomedical analysis 2004-01, Vol.34 (1), p.95-102
Hauptverfasser: Kurzawa, Marzanna, Kowalczyk-Marzec, Agnieszka
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Conductometric, potentiometric and cyclic voltammetric (CV) titration methods are proposed for determination of oxytetracycline (OTC), commonly used in veterinary. The electrochemical titration of OTC hydrochloride with NH 4Mo 7O 24, NaVO 3, NaOH, AgNO 3 and FeCl 3 as titrants are reported. The proposed methods were found to be highly precise, having a relative standard deviation (R.S.D.) below 1.0%. Proposed electrochemical titrations were successfully applied to the assay of commercial preparations: Tetrox, Tetramutin ®OT and Neox, containing the above-mentioned antibiotics. The validity of the methods was tested by the recovery studies of standard addition to pharmaceuticals and results were found to be satisfactory.
ISSN:0731-7085
1873-264X
DOI:10.1016/j.japna.2003.08.010