Osseointegration of Osseotite® and machined titanium implants in autogenous bone graft. A histologic and histomorphometric study in dogs

: It has been shown that a roughened implant surface results in a higher percentage of bone to implant contact (%BIC) than a machined one. A modified implant surface using a dual thermo‐acid etching process (Osseotite®) has been introduced and evaluated clinically, mechanically and histologically. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical oral implants research 2004-02, Vol.15 (1), p.54-61
Hauptverfasser: Veis, Alexander A., Trisi, Paolo, Papadimitriou, Serafim, Tsirlis, Anastasios T., Parissis, Nikolaos A., Desiris, Angelos K., Lazzara, Richard J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:: It has been shown that a roughened implant surface results in a higher percentage of bone to implant contact (%BIC) than a machined one. A modified implant surface using a dual thermo‐acid etching process (Osseotite®) has been introduced and evaluated clinically, mechanically and histologically. The aim of the present study was the histological evaluation of the %BIC between the Osseotite® or machined surfaces and the autogenous bone graft. Twenty‐two custom‐made split‐type 10‐mm‐long implants having two opposing surfaces (Osseotite® and machined) were placed between the cranial and caudal dorsal iliac spine at the iliac wing of two adult mongrel dogs. An artificial bone defect was created leaving a 2 mm empty space around the coronal 5 mm of the implants, while the apical 5 mm was stabilized in the existing basal bone. The defects around the implants were filled with particulate autogenous bone graft, covered by an Osseoquest® membrane, and left to heal for 5 months. All inserted implants showed a complete integration in the bone tissue. It was found that the resulting %BIC at the Osseotite® surface was significantly higher than at the machined one in both regenerated (46.44±15.81% vs. 28.59±12.04%) and basal bone areas (32.32±15.09% vs. 17.25±7.40%). The findings of this study imply that the use of autogenous bone graft resulted in significantly higher %BIC values in the regenerated area than in the basal bone area itself, for both implant surfaces. Résumé Il a étéétabli qu'une surface implantaire rugueuse s'accompagnait d'un plus grand pourcentage de contact os‐implant (% BIC) qu'au niveau d'un implant usiné. Une surface implantaire modifiée utilisant un processus de mordançage thermoacide double (Osseotite®) a été introduite et évaluée cliniquement, mécaniquement et histologiquement. Le but de l'étude présente a été l'évaluation histologique du % BIC entre les surfaces Osseotite® ou machinées et le greffon osseux autogène. Vingt‐deux implants de 10 mm de longueur divisés en une surface Osseotite® et une surface usinée ont été placés au niveau de la crête iliaque de deux chiens adultes bâtards. Une lésion osseuse artificielle a été créée en laissant un espace vide de 2 mm autour des 5 mm coronaire de l'implant tandis que les 5 mm apicaux étaient stabilisés dans l'os basal existant. Les lésions autour des implants ont été remplies avec une greffe osseuse de particules autogènes et recouvertes par une membrane Osseoquest®, et laissées guérir durant 5 mo
ISSN:0905-7161
1600-0501
DOI:10.1111/j.1600-0501.2004.01004.x