Measurement of abdominal muscle thickness using M-mode ultrasound imaging during functional activities
Ultrasound imaging has been previously utilized in the measurement of muscle thickness and cross-sectional area in research studies, and advocated as a clinical biofeedback tool in the rehabilitation of transversus abdominis function following episodes of low back pain. This paper describes how the...
Gespeichert in:
Veröffentlicht in: | Manual therapy 2004-02, Vol.9 (1), p.41-44 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Ultrasound imaging has been previously utilized in the measurement of muscle thickness and cross-sectional area in research studies, and advocated as a clinical biofeedback tool in the rehabilitation of transversus abdominis function following episodes of low back pain. This paper describes how the thickness of the abdominal muscles can be quantified with a new measurement technique using M-mode ultrasound. The technique uses a custom-made transducer holder that facilitates measurement of muscle thickness changes during functional activity. Limitations of the technique and potential future applications are discussed. The M-mode ultrasound technique may provide an effective method for the non-invasive measurement of abdominal muscle thickness during functional activities. |
---|---|
ISSN: | 1356-689X 1532-2769 |
DOI: | 10.1016/S1356-689X(03)00069-9 |