Q-Switched Erbium:YAG Laser Corneal Trephination: Thermal Damage in Corneal Stroma and Cut Regularity of Nonmechanical Q-Switched Erbium:YAG Laser Corneal Trephination for Penetrating Keratoplasty
PURPOSETo assess stromal thermal damage and cut regularity induced by nonmechanical Q-switched Er:YAG laser corneal trephination for penetrating keratoplasty. METHODSCorneal trephination was performed in 80 enucleated porcine eyes by Q-switched (2.94-μm) Er:YAG laser, along with donor and recipient...
Gespeichert in:
Veröffentlicht in: | Cornea 2004-01, Vol.23 (1), p.50-60 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | PURPOSETo assess stromal thermal damage and cut regularity induced by nonmechanical Q-switched Er:YAG laser corneal trephination for penetrating keratoplasty.
METHODSCorneal trephination was performed in 80 enucleated porcine eyes by Q-switched (2.94-μm) Er:YAG laser, along with donor and recipient masks made of metal or ceramic. All combinations of 0.65- or 0.96-mm spot diameter and 45- or 50-mJ/pulse energy setting were used with each of the masks at a 5-Hz repetition rate. Corneas were processed for histologic examinations. Stromal thermal damage was quantified on PAS-stained slides, and cut regularity was assessed semiquantitatively on a scale from 0 (regular) to 3 (highly irregular). Transmission electron microscopy and scanning electron microscopy were performed on selected specimens.
RESULTSThe least thermal damage (mean ± SD = 6.2 ± 0.7 μm) was found in the donor ceramic group with 50-mJ/pulse energy and 0.65-mm spot diameter, while the best regularity of the cut (1.2 ± 0.4) was found in the donor ceramic group with 45-mJ pulse energy and 0.65-mm spot diameter. Thermal damage was less pronounced in donor than in recipient corneas (P < 0.01). Smaller spot diameter (0.65 mm) led to less thermal damage (P < 0.01) than the use of a 0.96-mm spot diameter. The differences in thermal damage between ceramic and metal masks were minimal.
CONCLUSIONSAfter Q-switched Er:YAG laser corneal trephination for nonmechanical penetrating keratoplasty, reproducible high cut regularity and low concomitant thermal damage were observed. This is an encouraging finding in the search for a nonmechanical trephine for penetrating keratoplasty combining high precision and low cost. |
---|---|