Leukocyte depletion filters: A comparison of efficiency

Four commercially available leukocyte depletion filters were evaluated using a flow cytometric technique to determine the efficiency of each type of filter. The Sepacell R‐500A® and the PALL RC50® were the most efficient in leukocyte depletion having a mean depletion percentage of 99.3% and 99.5%, r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of hematology 1990-11, Vol.35 (3), p.184-186
1. Verfasser: Bodensteiner, David C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Four commercially available leukocyte depletion filters were evaluated using a flow cytometric technique to determine the efficiency of each type of filter. The Sepacell R‐500A® and the PALL RC50® were the most efficient in leukocyte depletion having a mean depletion percentage of 99.3% and 99.5%, respectively. The PALL RC100® which is used for two units also had a 99.3% depletion with the first unit but with the second unit the depletion dropped to 94.2%. The Imugard IG‐500® had a 97.3% depletion. Red cell recovery ranged from 87.4% for the PALL RC50® to 92.2% for the Sepacell R‐500A®.
ISSN:0361-8609
1096-8652
DOI:10.1002/ajh.2830350308