Effect of Vibratory Acoustic Stimulation on the Duration of Fetal Heart Rate Monitoring Tests
ABSTRACT The ability of vibratory acoustic stimulation to shorten the duration of antepartum fetal heart rate monitoring was investigated by a randomized controlled trial. Vibratory acoustic stimulation did not shorten the overall duration of testing. This failure to improve the performance of antep...
Gespeichert in:
Veröffentlicht in: | American journal of perinatology 1990-07, Vol.7 (3), p.232-234 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ABSTRACT
The ability of vibratory acoustic stimulation to shorten the duration of antepartum fetal heart rate monitoring was investigated by a randomized controlled trial. Vibratory acoustic stimulation did not shorten the overall duration of testing. This failure to improve the performance of antepartum monitoring appeared to result from prolonged accelerations, which complicated one third of the tests in which vibratory acoustic stimulation was employed. Further investigation is warranted using less profound methods of fetal stimulation. |
---|---|
ISSN: | 0735-1631 1098-8785 |
DOI: | 10.1055/s-2007-999489 |