Effect of Vibratory Acoustic Stimulation on the Duration of Fetal Heart Rate Monitoring Tests

ABSTRACT The ability of vibratory acoustic stimulation to shorten the duration of antepartum fetal heart rate monitoring was investigated by a randomized controlled trial. Vibratory acoustic stimulation did not shorten the overall duration of testing. This failure to improve the performance of antep...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of perinatology 1990-07, Vol.7 (3), p.232-234
Hauptverfasser: Newnham, John P., Burns, Sybil E., Roberman, Brian D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:ABSTRACT The ability of vibratory acoustic stimulation to shorten the duration of antepartum fetal heart rate monitoring was investigated by a randomized controlled trial. Vibratory acoustic stimulation did not shorten the overall duration of testing. This failure to improve the performance of antepartum monitoring appeared to result from prolonged accelerations, which complicated one third of the tests in which vibratory acoustic stimulation was employed. Further investigation is warranted using less profound methods of fetal stimulation.
ISSN:0735-1631
1098-8785
DOI:10.1055/s-2007-999489